We describe the detector development for a balloon-borne wide-field hard X-ray (20 – 600 keV) telescope, ProtoEXIST. ProtoEXIST is a pathfinder for both technology and science of the proposed implementation of the Black Hole Finder Probe, Energetic X-ray Imaging Survey telescope (EXIST). The principal technology challenge is the development of large area, close-tiled modules of imaging CZT detectors (1000 cm for ProtoEXIST1). We review the updates of the detector design and package concept for ProtoEXIST1 and report the current development status of the CZT detectors, using calibration results of our basic detector unit – 2 x 2 x 0.5 cm CZT crystals with 2.5 mm pixels (8 x 8 array). The current prototype (Rev1) of our detector crystal unit (DCU) shows ~4.5 keV electronics noise (FWHM), and the radiation measurements show the energy resolution (FWHM) of the units is 4.7 keV (7.9%) at 59.5 keV, 5.6 keV (4.6%) at 122 keV, and 7.6 keV (2.1%) at 356 keV. The new (Rev2) DCU with revised design is expected to improve the resolution by ~30%.
منابع مشابه
Detector and Telescope Development for ProtoEXIST and Fine Beam Measurements of Spectral Response of CZT Detectors
We outline our plan to develop ProtoEXIST, a balloon-borne prototype experiment for the Energetic X-ray Imaging Survey Telescope (EXIST) for the Black Hole Finder Probe. EXIST will consist of multiple wide-field hard X-ray coded-aperture telescopes. The current design of the EXIST mission employs two types of telescope systems: high energy telescopes (HETs) using CZT detectors, and low energy t...
متن کاملThe Proposed High Energy Telescope (HET) for EXIST
The hard X-ray sky now being studied by INTEGRAL and Swift and soon by NuSTAR is rich with energetic phenomena and highly variable non-thermal phenomena on a broad range of timescales. The High Energy Telescope (HET) on the proposed Energetic X-ray Imaging Survey Telescope (EXIST) mission will repeatedly survey the full sky for rare and luminous hard X-ray phenomena at unprecedented sensitiviti...
متن کامل99mTc-MDP bone scintigraphy of the hand: comparing the use of novel cadmium zinc telluride (CZT) and routine NaI(Tl) detectors
BACKGROUND Cadmium zinc telluride (CZT) solid-state detectors have been recently introduced in the field of nuclear medicine in cardiology and breast imaging. The aim of the current study was to evaluate the performance of the novel detectors (CZT) compared to that of the routine NaI(Tl) in bone scintigraphy. A dual-headed CZT-based camera dedicated originally to breast imaging has been used, a...
متن کاملThe Cadmium Zinc Telluride (CZT) Detector Array Innovation Pathway
This pathway describes the development of soft gamma-ray/hard x-ray detector arrays at NASA’s Goddard Space Flight Center (GSFC, or Goddard), through a collaboration between the gamma-ray spectroscopy group and the detector branch. The Cadmium Zinc Telluride (CdZnTe, or CZT) detectors which resulted from this decade-long development were first flown on the wildly successful SWIFT mission in 200...
متن کاملDesign and Testing of a Prototype Pixellated CZT Detector and Shield for Hard X-Ray Astronomy
We report on the design and laboratory testing of a prototype imaging CZT detector intended for balloon flight testing in April 2000. The detector tests several key techniques needed for the construction of large-area CZT arrays, as required for proposed hard X-ray astronomy missions. Two 10 mm × 10 mm × 5 mm CZT detectors, each with a 4 × 4 array of 1.9 mm pixels on a 2.5 mm pitch, will be mou...