Randomized trial of a nonpolymer-based rapamycin-eluting stent versus a polymer-based paclitaxel-eluting stent for the reduction of late lumen loss.

نویسندگان

  • Julinda Mehilli
  • Adnan Kastrati
  • Rainer Wessely
  • Alban Dibra
  • Jörg Hausleiter
  • Birgit Jaschke
  • Josef Dirschinger
  • Albert Schömig
چکیده

BACKGROUND Although drug-eluting stents (DESs) constitute a major achievement in preventing restenosis, concerns remain regarding the increased inflammatory and thrombogenic responses associated with the polymers used. Recently, we showed that a nonpolymer on-site coating with rapamycin not only is feasible and safe but also leads to a dose-dependent reduction in restenosis. METHODS AND RESULTS To assess whether polymer-free stents coated on-site with 2% rapamycin solution are inferior to polymer-based paclitaxel-eluting stents for the prevention of restenosis, we randomly assigned a total of 450 patients with de novo lesions in native coronary vessels, excluding the left main trunk, to either the polymer-free, rapamycin-coated Yukon DES (rapamycin stent) or the polymer-based, paclitaxel-eluting Taxus stent (paclitaxel stent). The primary end point was in-stent late lumen loss. Secondary end points were angiographic restenosis and target lesion revascularization. The study was designed to test the noninferiority of the rapamycin stent compared with the paclitaxel stent with respect to late lumen loss according to a noninferiority margin of 0.13 mm. Follow-up angiography was completed in 81% of the patients. The mean difference in in-stent late lumen loss between the rapamycin-stent group and the paclitaxel-stent group was 0.002 mm, and the upper limit of the 1-sided 95% confidence interval was 0.10 mm (P=0.02 from test for noninferiority). No significant differences were observed regarding angiographic restenosis rates (14.2% with the rapamycin stent and 15.5% with the paclitaxel stent) and target lesion revascularization rates due to restenosis (9.3% in both groups). CONCLUSIONS The polymer-free, rapamycin-coated stent has an antirestenotic effect that is not inferior to that observed with the polymer-based paclitaxel-eluting stent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polymer-free sirolimus-eluting versus polymer-based paclitaxel-eluting stents: an individual patient data analysis of randomized trials.

INTRODUCTION AND OBJECTIVES The angiographic and clinical efficacy of polymer-free sirolimus-eluting stents vs polymer-based paclitaxel-eluting stents remain a matter of debate. We sought to investigate angiographic and clinical measures of efficacy of polymer-free sirolimus-eluting stents vs polymer-based paclitaxel-eluting stents. METHODS Patient data from the randomized intracoronary stent...

متن کامل

Randomized comparison of a polymer-free sirolimus-eluting stent versus a polymer-based paclitaxel-eluting stent in patients with diabetes mellitus: the LIPSIA Yukon trial.

OBJECTIVES The objective of the study was to assess noninferiority of the polymer-free sirolimus-eluting Yukon Choice stent (Translumina GmbH, Hechingen, Germany) compared with the polymer-based Taxus Liberté stent (Boston Scientific, Natick, Massachusetts) with regard to the primary endpoint, in-stent late lumen loss, at 9 months in patients with diabetes mellitus. BACKGROUND The Yukon Choic...

متن کامل

Randomized trial of rapamycin- and paclitaxel-eluting stents with identical biodegradable polymeric coating and design.

AIMS This prospective, randomized study sought to directly compare the performance of paclitaxel and rapamycin on an otherwise identical, polymer-coated drug-eluting stent (DES) platform. METHODS AND RESULTS Stents with identical design and biodegradable polymeric coating that elute either rapamycin or paclitaxel over a 2 months time period were utilized. In this pilot trial that included 91 ...

متن کامل

Rationale and design for the PAINT randomized trial.

BACKGROUND We describe the rationale and design for the 'PercutAneous INTervention with biodegradable-polymer based paclitaxel-eluting or sirolimus-eluting versus bare stents for de novo coronary lesions - PAINT trial'. OBJECTIVES To evaluate two novel formulations of paclitaxel-eluting stent and the sirolimus-eluting stent against a stent with the same metallic structure but without polymer ...

متن کامل

Randomized comparison between polymer-free versus polymer-based paclitaxel-eluting stent: two-year final clinical results.

BACKGROUND Most drug-eluting stents currently in use are coated with a polymer carrying the drug that is released for several weeks. However, a durable polymer may provoke hypersensitive reaction, delayed artery healing, and eventually stent thrombosis. The aim of this study was to investigate the safety and efficacy of a polymer-free paclitaxel-eluting stent (PF-PES) versus a polymer-based PES...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 113 2  شماره 

صفحات  -

تاریخ انتشار 2006