Analysis and future trend of short-circuit power
نویسندگان
چکیده
A closed-form expression for short-circuit power dissipation of CMOS gates is presented which takes short-channel effects into consideration. The calculation results show good agreement with the SPICE simulation results over wide range of load capacitance and channel length. The change in the short-circuit power, , caused by the scaling in relation to the charging and discharging power, , is discussed and it is shown that basically power ratio, ( + ), will not change with scaling if TH DD is kept constant. This paper also handles the short-circuit power of series-connected MOSFET structures which appear in NAND and other complex gates.
منابع مشابه
Recognition and Location of Power Transformer Turn to Turn Fault by Analysis of Winding Imposed Forces
Turn to turn fault is one of the major internal failures in the power transformers that if it is not quickly detected, can be extended and led to a complete transformer breakdown. So, the diagnosis and location of the turn to turn fault of the power transformer, as one of the most important equipment in the power system, is the main objective of this paper. For this purpose, a detailed model of...
متن کاملDetermination of Optimal Allocation and Penetration Level of Distributed Energy Resources Considering Short Circuit Currents
The integration of Distributed Energy Resources (DER) in the distribution network has plenty of advantages if their allocation and Penetration Level (PL) are done appropriately. Hence, the challenge of finding the best allocation and PL of DERs in large distribution networks is an important but intricate problem. This paper proposes a novel methodology to simultaneously determine the optimal lo...
متن کاملAn Innovative Simple Test Circuit for Single-Phase Short Circuit Making Test of High-Voltage Switching Devices
Nowadays, high-voltage circuit breakers have reached such high short-circuit capabilities that testing them under the full rated voltage is generally not possible with direct tests, and they are conducted by using the synthetic test methods. Although the phenomena associated with making tests is of particular importance especially in case of load break switches, but making tests are rather d...
متن کاملDecreasing Distribution Generation Effects on Grid Short Circuit Level Using Superconducting Fault Current Limiter Through Updating Relays Set-Points
Power system protection at transmission and distribution levels based on overcurrent relays is essential based on their properties such as detection, stability, high speed, backup and error correction accuracy. Since distributed generation sources are connected to the power grid, they not only increase the short circuit level of the grid, but also disrupt the set point of main and backup relays...
متن کاملInfluence of Converter and inverter on dynamic behavior of the GMAW process
This paper investigates the dynamic behavior of Gas Metal Arc Welding (GMAW) process for two types of power supplies –inverter and rectifier- for short circuit transfer mode. The large ripples on the rectifier power source are able to perturb the metal transfer mode. In this experimental work some operating points in the short circuit mode have been selected using an automatic pipeline welding ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- IEEE Trans. on CAD of Integrated Circuits and Systems
دوره 19 شماره
صفحات -
تاریخ انتشار 2000