Determination of aluminum in beverages by automated non-segmented continuous flow analysis with fluorescent detection of the lumogallion complex.
نویسنده
چکیده
A method for the automated determination of aluminum in a variety of beverages is described. The method utilizes lumogallion as a complexing agent in a buffer solution. The system is very similar to flow-injection analysis (FIA), however, the tubing id is larger than that typically used in FIA. Therefore, the system is best described as non-segmented continuous flow analysis using fluorescence spectroscopy detection. The method is extremely simple, requiring virtually no sample preparation and only one reagent. The instrument detection limit for aluminum is 0.012 microgram ml-1 and calibration is linear to 3 micrograms ml-1. Results from a variety of beverage matrices are discussed and compared with the frequently used 8-hydroxyquinolone method utilizing a chloroform extraction and fluorescence spectroscopy detection.
منابع مشابه
FLOW INJECTIOW DETERMINATION OF FLUORIDE BY MURTN-ALUMINUM REAGEM WITH SPECTROEUORIMIETRIC DETECTION
A flow injection system is reported for the determination of fluoride based on its effects on the fluorescence intensity of Al-morin complex at pH 3.0 in ethanol-warn mixture. The effect of important parameters such as excitation and emission wavelengths, pH, reagents concenkations, flow rate of the carrier stream, sample injection volume, time of measurepent and interferences are reported. ...
متن کاملDetermination of serum and urinary aluminum by HPLC with fluorometric detection of Al-lumogallion complex.
We describe a simple and sensitive HPLC method for quantifying aluminum (Al) in biological fluids by measuring the fluorescence of the Al-lumogallion complex (excitation wavelength 500 nm, emission wavelength 575 nm). Serum samples are deproteinized with 0.83 mol/L perchloric acid and centrifuged; the supernates are mixed with lumogallion reagent. Urine samples are pretreated with sodium hydrox...
متن کاملSilica gel modified with lumogallion for aluminum determination by spectroscopic methods.
Simple, easy to use and selective method of Al(III) sorption-spectroscopic (SS) determination was proposed. For this purpose, silica modified with tridecyloctadecylammonium chloride(SGII) using adsorption technique and glass slide modified with thin silica-poly(dimethyldiallyl-ammonium chloride) (SGI) composite film obtained by sol-gel technique were worked out. It was shown that lumogallion (L...
متن کاملSensitive detection of trace aluminium in biological tissues by confocal laser scanning microscopy after staining with lumogallion.
This paper describes a method for the sensitive detection of aluminium in biological tissues by real time confocal laser scanning microscopy after staining with lumogallion. The method enabled detection of aluminium > or = 9 micrograms g-1 in bone and is more sensitive than the conventional histochemical methods with aluminium and solochrome azurine, etc. Lumogallion reacts specifically with al...
متن کاملAl adjuvants can be tracked in viable cells by lumogallion staining.
The mechanism behind the adjuvant effect of aluminum salts is poorly understood notwithstanding that aluminum salts have been used for decades in clinical vaccines. In an aqueous environment and at a nearly neutral pH, the aluminum salts form particulate aggregates, and one plausible explanation of the lack of information regarding the mechanisms could be the absence of an efficient method of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Analyst
دوره 124 5 شماره
صفحات -
تاریخ انتشار 1999