Factors affecting the stability of reverse shoulder arthroplasty: a biomechanical study.
نویسندگان
چکیده
BACKGROUND Despite the success of reverse shoulder arthroplasty (RSA) in treating patients with painful pseudoparalytic shoulders, instability is a common complication and currently the factors affecting stability are not well understood. The objective of this study was to investigate a number of factors as well as the interactions between factors to determine how they affect the stability of the prosthesis. These factors included: active arm posture (abduction and abduction plane angles), loading direction, glenosphere diameter and eccentricity, and humeral socket constraint. METHODS Force required to dislocate the joint, determined using a biomechanical shoulder simulator, was used as a measure of stability. A factorial design experiment was implemented to examine the factors and interactions. RESULTS Actively increasing the abduction angle by 15° leads to a 30% increase in stability and use of an inferior-offset rather than a centered glenosphere improved stability by 17%. Use of a more constrained humeral socket also increased stability; but the effect was dependent on loading direction, with a 88% improvement for superior loading, 66% for posterior, 36% for anterior, and no change for inferior loading. Abduction plane angle and glenosphere diameter had no effect on stability. CONCLUSION Increased glenohumeral abduction and the use of an inferior-offset glenosphere were found to increase the stability of RSA. Additionally, use of a more constrained humeral socket increased stability for anterior, posterior, and superior loading. These identified factor effects have the potential to decrease the risk of dislocation following RSA.
منابع مشابه
Reverse Total Shoulder Arthroplasty for the Treatment Of Synovial Chondromatosis: A Case Report and Review of the Literature
Synovial chondromatosis affecting the glenohumeral joint is rare. Treatment primarily consists of arthroscopic loose body removal and synovectomy. Shoulder arthroplasty has been mentioned in the literature as a treatment option for patients with coexisting arthritis, although the results have been underreported. The case of an 84-year-old man with long standing synovial chondromatosis of the sh...
متن کاملIdentification of Risk Factors for Abnormal Postoperative Chemistry Labs after Primary Shoulder Arthroplasty
Purpose Purpose The purpose of this study was to determine patient-specific risk factors and clinical intervention rates for abnormal postoperative Chem-7 panels in shoulder arthroplasty patients. Methods Retrospectively, all primary anatomic total (aTSA) and reverse shoulder (RTSA) arthroplasties (between 2007-2013) performed at a single institution were identified. All patients underwent ro...
متن کاملThe Perioperative Impact of Surgical Case Order in Primary Total Shoulder Arthroplasty
Background: The purpose of this study was to determine a correlation between surgical case order and the length ofoperative time, total length of time in the operating room, time until discharge from the hospital, and the incidence ofintraoperative complications for primary total shoulder arthroplasty cases.Methods: A retrospective review was conducted of records for all individual primary tota...
متن کاملEffect of lateral offset center of rotation in reverse total shoulder arthroplasty: a biomechanical study.
BACKGROUND Lateral offset center of rotation (COR) reduces the incidence of scapular notching and potentially increases external rotation range of motion (ROM) after reverse total shoulder arthroplasty (rTSA). The purpose of this study was to determine the biomechanical effects of changing COR on abduction and external rotation ROM, deltoid abduction force, and joint stability. MATERIALS AND ...
متن کاملShort-Term Results of the DePuy Global Unite Platform Shoulder System: A Two-Year Outcome Study
Background: The Global Unite Shoulder System is the next generation of implant from the Depuy Global Shoulderline. The primary feature of the Global Unite is adaptability through the interchangeable modular bodies, modular suturecollars, and stems. Short-term functional and radiographic outcomes of the Global Unite Platform Shoulder Systemwere assessed as well as complication and revision rates...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of shoulder and elbow surgery
دوره 22 4 شماره
صفحات -
تاریخ انتشار 2013