Aqueous Cr(VI) reduction by electrodeposited zero-valent iron at neutral pH: acceleration by organic matters.

نویسندگان

  • Junxi Liu
  • Chuan Wang
  • Jianying Shi
  • Hong Liu
  • Yexiang Tong
چکیده

This work investigated the effect of co-existing organic matters on aqueous Cr(VI) reduction by electrodeposited zero-valent iron (ED Fe(0)) at neutral pH. The ED Fe(0) prepared in a solution containing mixture of saccharin, L-ascorbic acid and sodium dodecyl sulfate showed higher activity in reducing the aqueous Cr(VI) at neutral pH than that prepared without any organic presence. XRD and SEM indicated that the structure of ED Fe(0) was significantly improved to nano-scale by the presence of organic mixture in the preparation solution. Further, the ED Fe(0) activity in the Cr(VI) reduction at neutral pH was increased by the co-existence of citric acid or oxalic acid in the chromate solution. Electrochemical impedance spectroscopy (EIS) demonstrated that the corrosive current increased with the concentration of organic matter in the reaction solution. With the co-existing organic matters in the preparation solution, the ED Fe(0) corroded more rapidly due to its nano-size, thus the Cr(VI) reduction by the ferrous iron was accelerated. With the co-existing organic matters in the reaction solution, the Cr(VI) reduction was accelerated by a Fe(II) complex as the main electron donor, and a prevention of the passivation due to the Fe(III) and Cr(III) complexes also accelerated the Cr(VI) reduction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

حذف کروم شش ظرفیتی از محیط های آبی با استفاده از نانو ذرات آهن تولید شده

Background and Objectives:Groundwater treatment by nano particles has received increasing interest in recent years. Chromium is a commonly identified contaminant in soils and groundwater. Zero-valent iron, as a natural reduction agent can be used in controlling of contaminated sites. The aim of this research is investigation of hexavalent chromium removal from aqueous solutions by using of iron...

متن کامل

Synthesis, characterization and re-activation of a Fe0/Ti system for the reduction of aqueous Cr(VI).

The conventionally employed zero-valent iron (Fe0) particles suffer a formation of surface oxides to lower their activity prior to use. During their using process for contaminant remediation, such oxide formation is also encountered, while the cumbersome handling of particles impedes the Fe0 recovery. To conquer the drawbacks, a Fe0 film was synthesized by electrodepositing ferrous ion cathodic...

متن کامل

Application of synthesized nanoscale zero-valent iron in the treatment of dye solution containing Basic Yellow 28

Nanoscale zero-valent iron NZVI particles were synthesized by the aqueous phase borohydride reduction method, and the synthesized NZVI particles were used for the degradation of Basic Yellow 28 BY28 dye in aqueous solution. The influence of experimental variables such as reaction time, NZVI particle dosage and pH were studied on the decolorization of BY28. Mixing an aqueous solution of 100 mg L...

متن کامل

Zero Valent Iron (ZVI) nanocomposite for the removal of hexavalent chromium from aqueous solution

S. Ponmani and C. Udayasoorian Abstract -A new class of nano scale zero valent iron (nZVI) particles supported on activated carbon (AC) were synthesized and the feasibility of using nanocomposite (AC+nZVI) for the removal of Cr(VI) in water was investigated through laboratory batch test. Nanocomposite was synthesized by impregnating carbon with ferrous sulfate followed by chemical reduction wit...

متن کامل

Immobilization of chromate in hyperalkaline waste streams by green rusts and zero-valent iron.

Zero-valent iron (ZVI) and green rusts can be used as reductants to convert chromium from soluble, highly toxic Cr(VI) to insoluble Cr(III). This study compared the reduction rates of Cr(VI) by ZVI and two carbonate green rust phases in alkaline/hyperalkaline solutions. Batch experiments were carried out with synthetic chromate solutions at pH 7.7-12.3 and a chromite ore processing residue (COP...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of hazardous materials

دوره 163 1  شماره 

صفحات  -

تاریخ انتشار 2009