Implantable Cardioverter-Defibrillator Implantation in a Patient with Atrial Standstill
نویسندگان
چکیده
We report a 55-year-old female patient who presented with no P waves but with a wide QRS complex escape rhythm at 44 beats/min and prolonged QTc of 0.55 seconds on ECG. The patient had recurrence of ventricular fibrillations and loss of consciousness, and underwent defibrillation and cardiopulmonary resuscitation (CPR) several times because of cardiac arrest. The transthoracic echocardiography showed dilated cardiomyopathy and enlargement of both atria. The Doppler echocardiography documented the absence of A wave in the tricuspid and mitral valve flow. An electrophysiologic study demonstrated electrical inactivity in the right and left atria. Atrial pacing with maximum output did not capture the atria. These findings together with her electrocardiographic finding indicated atrial standstill. Sudden cardiac death was her first clinical manifestation of ventricular arrhythmia. The patient remained asymptomatic after receiving a single chamber implantable cardioverter-defibrillator (ICD) with VVI pacemaker function.
منابع مشابه
Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus
Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...
متن کاملSuccess of Device-Based Methods for Atrial Tachyarrhythmia Induction during Implantation of an Implantable Cardioverter Defibrillator with Atrial Therapy
In addition to standard ventricular therapy, cardioversion using an implantable cardioverter defibrillator (ICD) with atrial therapy is one of the many new options available for treating atrial tachyarrhythmias. New data suggest that shock efficacy for AF depends on identifying atrial defibrillation thresholds (DFT) and programming the first atrial shock to at least two times the atrial DFT [1]...
متن کاملTHE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملزندگی با دفیبریلاتور قابل کاشت: یک مطالعه پدیدهشناسی
Background & Aim: Implantable Cardioverter Defibrillator is the most effective treatment for cardiac dysrhythmias. Having such life-saving device is the unique experience with important changes in the patient’ life. Understanding of these experiences can lead to success in treatment and follow- up.This study aimed to understand the experiences of patients with Implantable Cardioverter Defibri...
متن کاملArrhythmia/Electrophysiology Implantable Cardioverter-Defibrillator Registry Risk Score Models for Acute Procedural Complications or Death After Implantable Cardioverter-Defibrillator Implantation
Background—Patients undergoing implantable cardioverter-defibrillator (ICD) implantation are at risk of postprocedural complications. However, we do not have a risk stratification schema to identify patients at high and low risk of adverse events. Methods and Results—We analyzed data from 268 701 ICD implants submitted to the ICD Registry and developed logistic regression models to identify var...
متن کامل