Relative detection efficiency of back- and front-illuminated charge-coupled device cameras for X-rays between 1 keV and 18 keV.
نویسندگان
چکیده
High-resolution x-ray measurements were performed with a von Hamos-type bent crystal spectrometer using for the detection of the diffracted photons either a back-illuminated charge-coupled device (CCD) camera or a front-illuminated one. For each CCD the main x-ray emission lines (e.g., Kalpha, Kbeta, Lalpha, and Lbeta) of a variety of elements were measured in order to probe the performances of the two detectors between 1 and 18 keV. From the observed x-ray lines the linearity of the energy response, the noise level, the energy resolution, and the quantum efficiency ratio of the two CCDs were determined.
منابع مشابه
Background study for the pn-CCD detector of CERN Axion Solar Telescope
The CERN Axion Solar Telescope (CAST) experiment searches for axions from the Sun converted into photons with energies up to around 10 keV via the inverse Primakoff effect in the high magnetic field of a superconducting Large Hadron Collider (LHC) prototype magnet. A backside illuminated pn-CCD detector in conjunction with an X-ray mirror optics is one of the three detectors used in CAST to reg...
متن کاملLatest results on Jovian disk X-rays from XMM-Newton
We present the results of a spectral study of the soft X-ray emission (0.2−2.5 keV) from low-latitude (‘disk’) regions of Jupiter. The data were obtained during two observing campaigns with XMM-Newton in April and November 2003. While the level of the emission remained approximately the same between April and the first half of the November observation, the second part of the latter shows an enh...
متن کاملTime-Resolved Detection of X-rays Using Large-Area Avalanche Photodiodes
We have measured the efficiencies and time responses of several largearea (200 and 80 mm2) beveled-edge avalanche photodiodes to x-rays of energy 6–20 keV in a photon counting mode. The diodes were used with avalanche gains of 102 to 103. Detector efficiency varied from ∼50% at 8 keV to ∼5% at 20 keV, while the time resolution was ∼1/2 ns with a tail out to longer times (∼5 ns). The duration of...
متن کاملApplication of characteristic X-rays to measure linear attenuation coefficient of nano-composites used in shielding
Using of X-rays in different industries and especially in medical application is increasing. In this regard, designing of light and efficient protective material based on polymeric nanocomposites and precise study of the effect of adding nanoparticles with different sizes on the X-ray attenuation is necessary. In this study the epoxy nanocomposites with different percentages of copper oxide nan...
متن کاملSuzaku Observations of Near-relativistic Outflows in the Bal Quasar Apm 08279+5255
We present results from three Suzaku observations of the z = 3.91 gravitationally lensed broad absorption line quasar APM 08279+5255. We detect strong and broad absorption at rest-frame energies of . 2 keV (low-energy) and 7–12 keV (high-energy). The detection of these features confirms the results of previous long-exposure (80–90 ks) Chandra and XMM-Newton observations. The low and high-energy...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 78 9 شماره
صفحات -
تاریخ انتشار 2007