Canaloplasty: circumferential viscodilation and tensioning of Schlemm canal using a flexible microcatheter for the treatment of open-angle glaucoma in adults: two-year interim clinical study results.
نویسندگان
چکیده
PURPOSE To evaluate 2-year postsurgical safety and efficacy of canaloplasty (circumferential viscodilation and tensioning of the inner wall of Schlemm canal) to treat open-angle glaucoma (OAG). SETTING Multicenter surgical sites. METHODS This international prospective study comprised adult OAG patients having glaucoma surgery or combined glaucoma-cataract surgery. Qualifying preoperative intraocular pressure (IOP) was at least 16 mm Hg and historical IOP, at least 21 mm Hg. The full circumference of the canal was viscodilated and a trabecular tensioning suture placed with a microcatheter. Primary outcome measures included IOP and glaucoma medication use. RESULTS At 24 months, all 127 eyes (127 patients) had a mean IOP of 16.0 mm Hg +/- 4.2 (SD) and mean glaucoma medication use of 0.5 +/- 0.8 (baseline values 23.6 +/- 4.8 mm Hg and 1.9 +/- 0.8 medications). Eyes with canaloplasty alone had a mean IOP of 16.3 +/- 3.7 mm Hg and 0.6 +/- 0.8 medications (baseline values 23.2 +/- 4.0 mm Hg and 2.0 +/- 0.8 medications). Eyes with combined glaucoma-cataract surgery had a mean IOP of 13.4 +/- 4.0 mm Hg and 0.2 +/- 0.4 medications (baseline values 23.1 +/- 5.5 mm Hg and 1.7 +/- 1.0 medications). The IOP and medication use results at all time points were statistically significant versus baseline (P <.001). The late postoperative follow-up identified 3 patients with elevated IOP. No other serious ocular or nonocular complications were reported. CONCLUSION Canaloplasty was safe and effective in reducing IOP in adult patients with OAG.
منابع مشابه
Risk of circumferential viscodilation in viscocanalostomy.
Rękas et al. 1report on a new technique for lavage of predescemetic hemorrhage and blood clot removal after canalostomy assisted using the iTrack microcatheter (Ellex, Inc.). We have been using canaloplasty since 2006. In the beginning we used a 6-0 polypropylene suture for the catheterization of Schlemm canal and placing of a tension suture. This technique was adapted from 360-degree trabeculo...
متن کاملExperimental circumferential canaloplasty with a new Schlemm canal microcatheter.
AIM To present a new, simple, inexpensive Schlemm canal microcatheter for circumferential canaloplasty in a rabbit model. METHODS A rabbit glaucoma animal model was established by intravitreal injection of triamcinolone acetonide. Circumferential canaloplasty with a new Schlemm canal microcatheter (patent license number: 201220029850.0) was performed. The Schlemm canal microcatheter was compo...
متن کاملCanaloplasty for primary open-angle glaucoma: long-term outcome.
BACKGROUND/AIMS To study the safety and effectiveness of 360° viscodilation and tensioning of Schlemm canal (canaloplasty) in black African patients with primary open-angle glaucoma (POAG). METHODS Sixty randomly selected eyes of 60 consecutive patients with POAG were included in this prospective study. Canaloplasty comprised 360° catheterisation of Schlemm's canal by means of a flexible micr...
متن کاملCanaloplasty using iTrack 250 Microcatheter with Suture Tensioning on Schlemm's Canal
Open angle glaucoma (OAG) necessitating surgery has traditionally been treated with filtering procedures using antifibrotics. Unfortunately, such filtering procedures are not without the risk of postsurgical complications. Increasing interest in blebless surgery has led to innovative surgical procedures aimed at rejuvenating the natural trabeculo canalicular outflow pathway. Circumferential cat...
متن کاملCanaloplastyVA New Approach to Nonpenetrating Glaucoma Surgery
Canaloplasty is a new nonperforating glaucoma operation, which utilizes the experience with viscocanalostomy and adds a further surgical step to keep the ostia open and to stretch the trabecular meshwork permanently. During the operation, a deep sclerectomy and viscocanalostomy are performed as described by Stegmann et al. After this, a 200-2m microcatheter (iTrack; iScience Surgical Corp, Menl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 35 5 شماره
صفحات -
تاریخ انتشار 2009