Nondestructive analysis of urinary calculi using micro computed tomography
نویسندگان
چکیده
BACKGROUND Micro computed tomography (micro CT) has been shown to provide exceptionally high quality imaging of the fine structural detail within urinary calculi. We tested the idea that micro CT might also be used to identify the mineral composition of urinary stones non-destructively. METHODS Micro CT x-ray attenuation values were measured for mineral that was positively identified by infrared microspectroscopy (FT-IR). To do this, human urinary stones were sectioned with a diamond wire saw. The cut surface was explored by FT-IR and regions of pure mineral were evaluated by micro CT to correlate x-ray attenuation values with mineral content. Additionally, intact stones were imaged with micro CT to visualize internal morphology and map the distribution of specific mineral components in 3-D. RESULTS Micro CT images taken just beneath the cut surface of urinary stones showed excellent resolution of structural detail that could be correlated with structure visible in the optical image mode of FT-IR. Regions of pure mineral were not difficult to find by FT-IR for most stones and such regions could be localized on micro CT images of the cut surface. This was not true, however, for two brushite stones tested; in these, brushite was closely intermixed with calcium oxalate. Micro CT x-ray attenuation values were collected for six minerals that could be found in regions that appeared to be pure, including uric acid (3515 - 4995 micro CT attenuation units, AU), struvite (7242 - 7969 AU), cystine (8619 - 9921 AU), calcium oxalate dihydrate (13815 - 15797 AU), calcium oxalate monohydrate (16297 - 18449 AU), and hydroxyapatite (21144 - 23121 AU). These AU values did not overlap. Analysis of intact stones showed excellent resolution of structural detail and could discriminate multiple mineral types within heterogeneous stones. CONCLUSIONS Micro CT gives excellent structural detail of urinary stones, and these results demonstrate the feasibility of identifying and localizing most of the common mineral types found in urinary calculi using laboratory CT.
منابع مشابه
Limitations in Laboratory Stone Analysis: Micro-CT Attenuation Values Alone or FT-IR Alone Can be Unreliable Indicators of Mineral Type
Aims Early reports of micro computed tomography (micro CT) of urinary stones showed non-overlapping ranges of x-ray attenuation values for most minerals. However, extended work in our laboratory has shown that size of stone fragments and scanning parameters can each influence the apparent x-ray attenuation value of minerals. The purpose of the present study was to test the correlation of minera...
متن کاملEndourology and Stone Disease
Purpose: To evaluate the ultrastructural features of the urinary stones removed with endoscopic stone surgery, using micro computed tomography (micro-CT). Materials and Methods: Patients who had endoscopic surgery for renal or ureteral stones removal were included in this study. After surgery, the stones were classified into three groups and investigated with Skyscan 1174 micro-CT. Group I unde...
متن کاملMicro-Computed Tomography for the Evaluation of Bone Architecture
Micro-computed tomography (micro-CT) is an emerging technique for the nondestructive assessment and analysis of the three-dimensional trabecular bone structure. Trabecular bone consists of a complicated three-dimensional network of plates and rods, arranged in a lattice-like network [1]. Aging, disease process, and therapeutic agents could influence the number of elements in this network, their...
متن کاملDual-energy computed tomography with advanced postimage acquisition data processing: improved determination of urinary stone composition.
INTRODUCTION The characterization of urinary calculi using noninvasive methods has the potential to affect clinical management. CT remains the gold standard for diagnosis of urinary calculi, but has not reliably differentiated varying stone compositions. Dual-energy CT (DECT) has emerged as a technology to improve CT characterization of anatomic structures. This study aims to assess the ability...
متن کاملNondestructive Microcomputed Tomography Evaluation of Mineral Density in Exfoliated Teeth with Hypophosphatasia
Most cases of hypophosphatasia (HPP) exhibit early loss of primary teeth. Results of microcomputed tomography (micro-CT) analysis of teeth with HPP have rarely been reported. The purpose of the present study was to describe the mineral density distribution and mapping of exfoliated teeth from an HPP patient using micro-CT. Four exfoliated teeth were obtained from a patient with HPP. Enamel and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BMC Urology
دوره 4 شماره
صفحات -
تاریخ انتشار 2004