Digital cellular telephone interaction with implantable cardioverter-defibrillators.
نویسندگان
چکیده
OBJECTIVES This study sought to determine, in vivo, whether electromagnetic interference (EMI), generated by North American Digital Communications (NADC)/Time Division Multiple Access-50-Hz (TDMA-50) mobile cellular digital telephone model AT&T 6650, disturbs normal implantable cardioverter-defibrillator (ICD) operation and to verify these observations in vitro by testing a selection of telephones representing worldwide systems. METHODS The effects of cellular phone interference on the operation of various models of market-released ICDs from a single manufacturer, Medtronic, Inc., were tested. The in vivo clinical test was undertaken in 41 patients using the AT&T 6650 digital telephone with the NADC/TDMA-50 technology. The in vitro component of the study was examined twofold: 1) antenna generated far field; and 2) analog/digital cellular telephone near field. RESULTS None of the ICDs tested in 41 patients were affected by oversensing of the EMI field of the cellular telephones during the in vivo study. Therefore, the binomial upper 95% confidence limit for the failure rate of 0% is 7%. The in vitro antenna-generated field testing showed that telephone modulation frequencies used in the international Global System Mobile and TDMA-50 cellular telephone technologies did not result in ICD sensing interference at the predicted electric field intensity. The in vitro near field tests were performed using both analog and digital cellular telephones in service, or in the test mode, and indicated no interaction with normal operation. However, the static magnetic field generated by the cellular telephone placed over the ICD at a distance < or = 0.5 cm will activate the internal reed switch, resulting in temporary suspension of ventricular tachycardia and fibrillation detection. CONCLUSIONS We conclude that TDMA-50 cellular telephones did not interfere with these types of ICDs. However, we recommend that the patient not carry or place the digital cellular telephone within 15 cm (6 in.) of the ICD.
منابع مشابه
In-vivo testing of digital cellular telephones in patients with implantable cardioverter-defibrillators.
AIMS To investigate the susceptibility of implantable cardioverter defibrillators to electromagnetic interference generated by digital cellular telephones, functioning in both international transmission technologies: the Global System for Mobile Communication (GSM) and the Digital Cellular System (DCS 1800). METHODS AND RESULTS In 36 patients with transvenous implantable cardioverter defibril...
متن کاملiPad2® Use in Patients With Implantable Cardioverter Defibrillators Causes Electromagnetic Interference: The EMIT Study
BACKGROUND Over 140 million iPads(®) have been sold worldwide. The iPad2(®), with magnets embedded in its frame and Smart Cover and 3G cellular data capability, can potentially cause electromagnetic interference in implantable cardioverter defibrillators. This can lead to potentially life-threatening situations in patients. The goal of this study was to determine whether the iPad2(®) can cause ...
متن کاملElectromagnetic Interference in Patients with Implanted Cardioverter-Defibrillators and Implantable Loop Recorders
Introduction: Modern life exposes us all to an ever-increasing number of potential sources of electromagnetic interference (EMI) and patients with Implantable rhythm devices (IRD) like pacemakers, implantable cardioverter defibrillators or implantable loop recorders often ask about the use of microwave ovens, walking through airport metal detectors and the use of cellular phones. Electromagneti...
متن کاملImplantable cardioverter defibrillator during laser transurethral resection of the prostate
Implantable cardioverter defibrillators have been instrumental in the health and safety of patients who are at increased risk of sudden death by ventricular tachycardia or fibrillation. Consensus on the perioperative management of cardiovascular implantable electronic devices has suggested that certain surgical interventions (including transurethral resection of the prostate) may interfere wi...
متن کاملImplantable Cardioverter Defibrillators Proportion of patients needing an implantable cardioverter defibrillator on the basis of current guidelines: impact on healthcare resources in Italy and the USA. Data from the ALPHA study registry
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CLINICAL RESEARCH Implantable Cardi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American College of Cardiology
دوره 31 3 شماره
صفحات -
تاریخ انتشار 1998