Performance evaluation of the PelvoCheck CT/NG test kit for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae

نویسندگان

  • Thomas Meyer
  • Christian Klos
  • Regina Kofler
  • Annett Kilic
  • Kristina Hänel
چکیده

OBJECTIVE Assessment of the performance of the PelvoCheck CT/NG test (Greiner-Bio-One GmbH) to detect Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) in first-void urine (FVU) of females. DESIGN A cross-sectional study to compare the PelvoCheck CT/NG with COBAS TaqMan CT Test V.2.0 (Roche) for the detection of CT and with an in-house porA-based PCR for the detection of NG in FVU specimens. In addition, pools of 5 FVU specimens containing only CT-negative or 1 CT-positive and 4 CT-negative samples were tested. Abbott RealTime CT/NG was used as an additional test to resolve discordant results. SETTING Samples sent from six laboratories were tested at the University Medical Center Hamburg. PARTICIPANTS Urine samples were from 1622 female patients attending gynaecological practices for chlamydia screening, another 120 urine samples were from patients pretested for NG at Synlab, Medical Service Center, Weiden GmbH. In addition, 50 urine samples spiked with various concentrations of reference material were used. RESULTS For the detection of CT and NG, the sensitivity and specificity of the PelvoCheck CT/NG test were 98.8% and 100%, and 98.3% and 98.2%, respectively. The data obtained with the PelvoCheck CT/NG for pooled urine specimens resulted in a positive agreement of 90.9% and a negative agreement of 100%. CONCLUSIONS The PelvoCheck CT/NG assay is a suitable test method for the detection of CT and NG in female FVU samples, with sensitivity and specificity comparable with other Food and Drug Administration approved CT/NG nucleic acid amplification tests. To the best of our knowledge, this is the first commercial test system validated for the analysis of pooled urine specimens. No false-positive or invalid result was observed in 55 analysed pools. Nevertheless, 5 samples were false negative due to a target concentration below the limit of detection of the PelvoCheck CT/NG test as a consequence of pooling-associated dilution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in an STI population: performances of the Presto CT-NG assay, the Lightmix Kit 480 HT CT/NG and the COBAS Amplicor with urine specimens and urethral/cervicovaginal samples

OBJECTIVES This study assessed the performances of the Presto CT-NG assay, the Lightmix Kit 480 HT CT/NG and the COBAS Amplicor for Chlamydia trachomatis and Neisseria gonorrhoeae detection. DESIGN A cross-sectional study design. SETTING Izore, Centre for Diagnosing Infectious Diseases in Friesland, the Netherlands, tested samples sent from regional sexually transmitted infection (STI) outp...

متن کامل

Validation of a laboratory-developed real-time PCR protocol for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in urine.

OBJECTIVE To evaluate a sensitive and specific, real-time PCR assay with internal control for Chlamydia trachomatis and Neisseria gonorrhoeae DNA detection in urine specimens. METHODS The diagnostic performance of a laboratory-developed quadruplex assay (LDQA) targeting the cryptic plasmid and MOMP genes of C trachomatis, the porA pseudogene of N gonorrhoeae and a synthetic internal control w...

متن کامل

Multiplex AMPLICOR PCR Screening for Chlamydia trachomatis and Neisseria gonorrhoeae in Women Attending Non-Sexually Transmitted Disease Clinics

A new PCR kit (AMPLICOR CT/NG; Roche Diagnostic Systems, Inc., Branchburg, N.J.) was used as a screening tool for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae in first-void urine (FVU) specimens from 3,340 asymptomatic women attending European health care units for contraceptive advice or pregnancy termination. All samples were kept frozen (220°C) prior to testing. Chlamydia...

متن کامل

Evaluation of three automated nucleic acid amplification systems for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in first-void urine specimens.

A total of 500 first-void urine specimens were tested for the presence of Chlamydia trachomatis and Neisseria gonorrhoeae nucleic acids using ProbeTec ET reagents on a Viper platform (BD Diagnostics, Mississauga, Ontario, Canada), Aptima Combo 2 reagents on a Tigris platform (Gen-Probe, Inc., San Diego, CA), and Abbott RealTime CT/NG reagents on an m2000 platform (Abbott Molecular Diagnostics, ...

متن کامل

Evaluation of Abbott RealTime CT/NG Assay for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae in Cervical Swabs from Female Sex Workers in China

BACKGROUND To evaluate the performance of the Abbott RealTime CT/NG assay for detection of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) among female sex workers (FSWs) in China. METHODS Cervical swabs from 997 participants were blindly detected by the Abbott RealTime CT/NG assay on the automated m2000 molecular platform and Roche Cobas Amplicor CT/NG assay. Discrepant analysis we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016