Evaluation of skin dose associated with different frequencies of bolus applications in post-mastectomy three-dimensional conformal radiotherapy

نویسندگان

  • Fundagul Andic
  • Yasemin Ors
  • Rima Davutoglu
  • Sule Baz Cifci
  • Emine Burcin Ispir
  • Mehmet Ertugrul Erturk
چکیده

BACKGROUND The study aimed to calculate chest-wall skin dose associated with different frequencies of bolus applications in post-mastectomy three-dimensional conformal radiotherapy (3D-CRT) and to provide detailed information in the selection of an appropriate bolus regimen in this clinical setting. METHODS CT-Simulation scans of 22 post-mastectomy patients were used. Chest wall for clinical target volume (CTV) and a volume including 2-mm surface thickness of the chest wall for skin structures were delineated. Precise PLAN 2.11 treatment planning system (TPS) was used for 3D-CRT planning. 50 Gy in 25 fractions were prescribed using tangential fields and 6-MV photons. Six different frequencies of bolus applications (0, 5, 10, 15, 20, and 25) were administered. Cumulative dose-volume histograms were generated for each bolus regimen. The minimum, maximum and mean skin doses associated with the bolus regimens were compared. To test the accuracy of TPS dose calculations, experimental measurements were performed using EBT gafchromic films. RESULTS The mean, minimum and maximum skin doses were significantly increased with increasing days of bolus applications (p < 0.001). The minimum skin doses for 0, 5, 10, 15, 20, and 25 days of bolus applications were 73.0% +/- 2.0%, 78.2% +/- 2.0%, 83.3% +/- 1.7%, 88.3% +/- 1.6%, 92.2% +/- 1.7%, and 93.8% +/- 1.8%, respectively. The minimum skin dose increments between 20 and 25 (1.6% +/- 1.0%), and 15 and 20 (4.0% +/- 1.0%) days of bolus applications were significantly lower than the dose increments between 0 and 5 (5.2% +/- 0.6%), 5 and 10 (5.1% +/- 0.8%), and 10 and 15 (4.9% +/- 0.8%) days of bolus applications (p < 0.001). The maximum skin doses for 0, 5, 10, 15, 20, and 25 days of bolus applications were 110.1% +/- 1.1%, 110.3% +/- 1.1%, 110.5% +/- 1.2%, 110.8% +/- 1.3%, 111.2% +/- 1.5%, and 112.2% +/- 1.7%, respectively. The maximum skin dose increments between 20 and 25 (1.0% +/- 0.6%), and 15 and 20 (0.4% +/- 0.3%) days of bolus applications were significantly higher than the dose increments between 0 and 5 (0.2% +/- 0.2%), 5 and 10 (0.2% +/- 0.2%), and 10 and 15 (0.2% +/- 0.2%) days of bolus applications (p < or = 0.003). The TPS overestimated the near-surface dose 10.8% at 2-mm below the skin surface. CONCLUSION In post-mastectomy 3D-CRT, using a 1-cm thick bolus in up to 15 of the total 25 fractions increased minimum skin doses with a tolerable increase in maximum doses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Bolus Frequency and Its Thickness in Postmastectomy Three-dimensional Conformal Radiotherapy on Skin Dose for Superposition Algorithm

Introduction: The postmastectomy radiotherapy uses bolus to improve the coverage close to the skin; however, it needs to be removed in case of severe skin toxicity. This study investigated the effect of bolus parameters (i.e., frequency and thickness) for the superposition algorithm on skin dose in postmastectomy three-dimensional conformal radiotherapy (3D-CRT). <str...

متن کامل

On Presentation of Optimal Treatment Plan in Radiotherapy of Parotid Cancer: A Comparison of Nine Techniques in Three Dimensional Conformal Radiation Therapy

Introduction: Today, radiotherapy combined with surgery in the treatment of parotid tumors widely are used specially for high grade parotid tumors. One of concern and challenge issue of radiotherapy is that the treatment of these tumors with irregular surface due to the presence of external ear and region of different physical electron density (air cavities, dense bone, soft t...

متن کامل

Comparison of three different techniques in parotid gland tumors using three dimensional conformal radiation therapy

Introduction: Background: Radiotherapy of parotid tumors is achieved by different radiotherapy techniques. So they deliver the dose to organs at risk such as contralateral parotid, temporal lobe & spinal cord. The consequences of high dose to OARs are xerostomia, Temporal lobe necrosis and loss of hearing. Purpose: The aim of this study was to compare different treatment tech...

متن کامل

Clinical application of 3D-printed-step-bolus in post-total-mastectomy electron conformal therapy

The 3D-printed boluses were used during the radiation therapy of the chest wall in six patients with breast cancer after modified radical mastectomy (MRM). We measured the in-vivo skin doses while both conventional and 3D-printed boluses were placed on the chest wall and compared the mean doses delivered to the ipsilateral lung and the heart. The homogeneity and conformity of the dose distribut...

متن کامل

Dosimetric Study of Tissue Heterogeneity Correction for Breast Conformal Radiotherapy

Introduction: Heterogeneity correction is an important parameter in dose calculation for cancer patients where it may be cause inaccuracy in dose calculation as a result of different densities of patients. This study studied the impact of dose calculation of breast cancer patients with and without heterogeneity correction. Material and Methods: Twenty breast cancer patients were treated with Th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of Experimental & Clinical Cancer Research : CR

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2009