Bioabsorbable Versus Metal Screw in the Fixation of Tibial Tubercle Transfer: A Cadaveric Biomechanical Study

نویسندگان

  • Janne T. Nurmi
  • Ari Itälä
  • Raine Sihvonen
  • Petri Sillanpää
  • Pekka Kannus
  • Harri Sievänen
  • Teppo L.N. Järvinen
چکیده

BACKGROUND In tibial tubercle transfer (TTT) procedures, the osteotomized and transferred tibial tubercle is usually fixed into the host bone using metal screws. PURPOSE To compare the strength of fixation provided by a single bioabsorbable screw versus a metal screw for TTT. STUDY DESIGN Controlled laboratory study. METHODS Twenty-two pairs of human cadaveric tibiae were used to compare the fixation strength of a single 4.5-mm bicortical bioabsorbable or metal screw for TTT. In our 2-phase biomechanical testing protocol, the specimens were first subjected to a cyclic-loading test (1500 loading cycles between 50 and 300 N at 0.5 Hz frequency), after which they were loaded to failure (single-cycle load-to-failure test). To control for possible differences in bone quality, volumetric bone mineral density was determined using peripheral quantitative computed tomography. RESULTS No significant displacement differences were observed between the 2 groups for the cyclic-loading test. In the subsequent single-cycle load-to-failure test, the mean yield load was 566 ± 234 N in the bioabsorbable screw group and 984 ± 630 N in the metal screw group (P = .002). The failure mode of bioabsorbable screws was breakage and/or bending, and that of metal screws was bending and/or pull-out. Bone density was similar in the 2 groups. CONCLUSION A metal screw seems to provide greater fixation strength than a biodegradable screw in the TTT of a human cadaveric knee. However, considering the maximum quadriceps pull in vivo, the strength of fixation provided by a biodegradable screw seems clinically sufficient. CLINICAL RELEVANCE Bioabsorbable screws, particularly if used in duplicate, could provide a viable option for metal screws in TTT fixation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

Interference screw fixation of tendontransfers in the foot and ankle.

Tendon transfers pptay an important role in reconstructive foot and ankle surgery. Multiple methods for fixation of tendon to bone are used including suture of tendon to periosteum, suture into bone troughs, suture anchors, and passage through bone tunnels. With the increasing populatity of hamstring tendon anterior cruciate ligament reconstructions has come new fixation technology. Soft-tissue...

متن کامل

Self-reinforced bioabsorbable versus metallic fixation systems for metacarpal and phalangeal fractures: a biomechanical study.

Bioabsorbable fixation devices offer a useful option to treat small bone fractures of the hand if the prerequisite of reliable and stable osteofixation is met. We compared the stabilities of various bioabsorbable fixation devices with metallic fixation devices by using an oblique osteotomy model in radial to ulnar orientation. The 1.5-mm, self-reinforced, poly-L-lactide (SR-PLLA) pins provided ...

متن کامل

Early tension loss in an anterior cruciate ligament graft. A cadaver study of four tibial fixation devices.

BACKGROUND The tensile force applied to an anterior cruciate ligament graft determines the maximal anterior translation; however, it is unknown whether the tensile force is transferred to the intra-articular portion of the graft and whether the intra-articular tension and maximal anterior translation are maintained shortly after ligament reconstruction. METHODS Ten cadaveric knees were recons...

متن کامل

Surgical management of tibial tubercle fractures in association with tibial plateau fractures fixed by direct wiring to a locking plate.

Tibial tubercle fractures disrupting the extensor mechanism of the knee can occur in association with complex tibial plateau fractures (AO type 41A, B, C). The management of these fractures can be difficult; a stable repair of the tibial tubercle fragment is essential if the extensor mechanism is to be reconstituted. There are few reported techniques described to manage tibial tubercle fracture...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017