A 72-hour study to test the efficacy and safety of the "Mucus Slurper" in mechanically ventilated sheep.
نویسندگان
چکیده
OBJECTIVE In patients intubated with endotracheal tubes (ETTs), suctioning is routinely performed to remove mucus from within the ETT and trachea. The Mucus Slurper is a novel ETT with built-in suction ports arranged radially at its tip. We evaluated the safety and efficacy of the Mucus Slurper, compared with conventional tracheal suction, to prevent airway obstruction in sheep with the ETT and trachea oriented below horizontal. DESIGN Prospective randomized animal study. SETTING Animal research facility at the National Institutes of Health. SUBJECTS Twelve healthy sheep. INTERVENTIONS Sheep were randomized to be intubated with either the Mucus Slurper (study group) or a Hi-Lo Tracheal Tube (Mallinckrodt, St. Louis, MO) (control group) and mechanically ventilated for 72 hrs. In the study group, automatic, timed tracheal aspiration lasted 0.3 secs, was repeated every 2 mins, and was synchronized with the early expiratory phase. In the control group, tracheal suction was performed every 6 hrs or as required. MEASUREMENTS AND MAIN RESULTS In the control group, tracheal secretions accumulated progressively within the ETT and the trachea. In the study group, all mucus that reached the tip of the Mucus Slurper was aspirated, keeping the lumen of the ETT, and proximal trachea, free from secretions. In the study group, expiratory water trap protein concentration, a crude index to measure mucus drainage through the ETT, was consistently less than the control group (p < .001). At autopsy, no macroscopic injury to the tracheal mucosa was found in either group. In the study group, the respiratory circuit was less colonized than in the control group. There were no statistically significant differences between the two groups in bacterial colonization of the lungs/bronchi. CONCLUSIONS The Mucus Slurper, combined with orientation of the trachea below horizontal, prevents accumulation of secretions within the lumen of the ETT and trachea, without need for conventional tracheal suctioning.
منابع مشابه
Effect of Oral Drop Gastrolit (Zataria multiflora) on Gastric Residual Volume in Mechanically Ventilated Patients Hospitalized in the Intensive Care Units
Background: Proper nutritional support is one of the important caring aspects in patients who were hospitalized in ICU. Objective: This study was done to investigate Oral Drop Gastrolit effect on the gastric residual volume (GRV) in mechanically ventilated patients hospitalized in ICU. Methods: In this clinical trial, 50 mechanically ventilated patients were recruited using convenience sampli...
متن کاملEffect of Acupressure on Gastric Content Aspiration in Mechanically Ventilated Patients Hospitalized in Intensive Care Units
Background and Objectives: Aspiration is a serious complication that occurs due to delayed gastric emptying in mechanically ventilated patients. Aspiration results in increased rate of pneumonia and death. Acupressure can increase gastric motility and prevent aspiration. This study aimed to determine the effect of acupressure on occurrence of gastric content aspiration in mechanically ventilate...
متن کاملPharmacokinetics Alterations of Midazolam Infusion versus Bolus Administration in Mechanically Ventilated Critically Ill Patients
There is no randomized study carried out in order to compare their pharmacokinetic parameters although midazolam, as a sedative, has been widely administered via continuous infusion as well as intermittent bolus doses in mechanically ventilated critically ill patients. We prospectively investigated the effect of these two principal methods on pharmacokinetic parameters in 23 of mentioned patien...
متن کاملPharmacokinetics Alterations of Midazolam Infusion versus Bolus Administration in Mechanically Ventilated Critically Ill Patients
There is no randomized study carried out in order to compare their pharmacokinetic parameters although midazolam, as a sedative, has been widely administered via continuous infusion as well as intermittent bolus doses in mechanically ventilated critically ill patients. We prospectively investigated the effect of these two principal methods on pharmacokinetic parameters in 23 of mentioned patien...
متن کاملمقایسه تاثیر دو روش ساکشن باز و بسته بر دیس ریتمی های قلبی بیماران تحت تهویه مکانیکی
Background: Nowadays, due to an increase in patients require intensive care, application of mechanical ventilation and endotracheal tube is necessary. In order to Keeping an open airway, endotracheal suctioning is necessary. Select the appropriate suction method can reduce the severe complications. The aim of this study is comparing the efficacy of open and closed suctioning on heart disrhythmi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Critical care medicine
دوره 35 3 شماره
صفحات -
تاریخ انتشار 2007