Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre.

نویسندگان

  • M Cannesson
  • O Desebbe
  • P Rosamel
  • B Delannoy
  • J Robin
  • O Bastien
  • J-J Lehot
چکیده

BACKGROUND Respiratory variations in pulse oximetry plethysmographic waveform amplitude (DeltaPOP) can predict fluid responsiveness in mechanically ventilated patients but cannot be easily assessed at the bedside. Pleth variability index (PVI) is a new algorithm allowing for automated and continuous monitoring of DeltaPOP. We hypothesized that PVI can predict fluid responsiveness in mechanically ventilated patients under general anaesthesia. METHODS Twenty-five patients were studied after induction of general anaesthesia. Haemodynamic data [cardiac index (CI), respiratory variations in arterial pulse pressure (DeltaPP), DeltaPOP, and PVI] were recorded before and after volume expansion (500 ml of hetastarch 6%). Fluid responsiveness was defined as an increase in CI > or =15%. RESULTS Volume expansion induced changes in CI [2.0 (sd 0.9) to 2.5 (1.2) litre min(-1) m(-2); P<0.01], DeltaPOP [15 (7)% to 8 (3)%; P<0.01], and PVI [14 (7)% to 9 (3)%; P<0.01]. DeltaPOP and PVI were higher in responders than in non-responders [19 (9)% vs 9 (4)% and 18 (6)% vs 8 (4)%, respectively; P<0.01 for both]. A PVI >14% before volume expansion discriminated between responders and non-responders with 81% sensitivity and 100% specificity. There was a significant relationship between PVI before volume expansion and change in CI after volume expansion (r=0.67; P<0.01). CONCLUSIONS PVI, an automatic and continuous monitor of DeltaPOP, can predict fluid responsiveness non-invasively in mechanically ventilated patients during general anaesthesia. This index has potential clinical applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does the Pleth variability index indicate the respiratory-induced variation in the plethysmogram and arterial pressure waveforms?

BACKGROUND Respiratory variations in the pulse oximeter plethysmographic waveform amplitude (deltaPOP) are sensitive to changes in preload and can predict fluid responsiveness in mechanically ventilated patients. However, they cannot be easily calculated from a bedside monitor. Pleth variability index (PVI, Masimo Corp., Irvine, CA) is a new algorithm that automatically calculates deltaPOP. The...

متن کامل

The Pulse Oximeter Plethysmographic Waveform Reflects Changes That Occur during the Respiratory Cycle

Many pulse oximetry technologies display a processed and filtered representation of the photoplethysmosgraphic waveform. Each manufacturer uses unique proprietary algorithms to calculate the waveform displayed on the pulse oximeter. Masimo has extracted and processed information from the waveform to create two physiologic indices, perfusion index (PI) and pleth variability index (PVI). PI is ca...

متن کامل

The Pulse Oximeter Plethysmographic Waveform Reflects Changes That Occur during the Respiratory Cycle

Many pulse oximetry technologies display a processed and filtered representation of the photoplethysmosgraphic waveform. Each manufacturer uses unique proprietary algorithms to calculate the waveform displayed on the pulse oximeter. Masimo has extracted and processed information from the waveform to create two physiologic indices, perfusion index (PI) and pleth variability index (PVI). PI is ca...

متن کامل

Pleth variability index is a weak predictor of fluid responsiveness in patients receiving norepinephrine.

BACKGROUND In patients receiving an infusion of norepinephrine, the relationship between the amplitude of the oximeter plethysmographic waveform and stroke volume may be variable and quality of the waveform might be reduced, compared with patients not receiving norepinephrine. We assessed the reliability of the pleth variability index (PVI), an automatic measurement of the respiratory variation...

متن کامل

Respiratory variations in pulse oximetry plethysmographic waveform amplitude to predict fluid responsiveness in the operating room.

BACKGROUND Respiratory variations in pulse oximetry plethysmographic waveform amplitude (DeltaPOP) are related to respiratory variations in pulse pressure (DeltaPP) and are sensitive to changes in preload. The authors hypothesized that DeltaPOP can predict fluid responsiveness in mechanically ventilated patients during general anesthesia. METHODS Twenty-five patients referred for cardiac surg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 101 2  شماره 

صفحات  -

تاریخ انتشار 2008