Spectrophotometric determination of carbon monoxide with ruthenium(II) octaethylporphyrin.
نویسندگان
چکیده
A novel spectrophotometric method for the estimation of carbon monoxide at levels from 2 to 250 ppm is presented. The method is empirical and based on formation of a carbonyl complex of ruthenium(II) octaethylporphyrin and measurement of the difference in absorbance at 393.5 nm between this complex and the porphyrin reagent. Oxygen and nitrogen do not interfere and up to 300 ppm of sulphur dioxide and about 1500 ppm of carbon dioxide can be tolerated in determination of carbon monoxide at the 4 and 10 ppm levels. Hydrogen sulphide interferes and must be removed before the determination. The method has been tested over the range 2-45 ppm of carbon monoxide with 16 synthetic and 2 commercial standard air samples. The average error was +/- 3%. Application to urban-air samples and car-exhaust gases yielded acceptable results. The main disadvantages are the tedious preparation of the initial ruthenium(III)-porphyrin compound and the decomposition of the reagent in the presence of hydrazine.
منابع مشابه
A modification of the spectrophotometric determination of carbon monoxide in blood enabling direct determination of per cent hemoglobin saturation.
BECAUSE OF VARIATION in hemoglobin concentration in normal bloods with age and sex (1), the per cent carbon monoxide saturation of hemoglobin represents a more accurate toxicity index than the volume per cent of carbon monoxide. In 2 of the most common methods of carbon monoxide determination in blood, the gasometric method of Van Slyke (2, 3, 4) and the spectrophotometric method of Harper (5),...
متن کاملPreparation of ruthenium(II) and ruthenium(III) myoglobin and the reaction of dioxygen, and carbon monoxide, with ruthenium(II) myoglobin.
Ruthenium myoglobins have been prepared by the reconstitution of horse heart apomyoglobin with either ruthenium(II) or ruthenium(III) mesoporphyrin IX (MpIX) derivatives. The ruthenium(II) and -(III) myo globins (RuMb and RuMb+, respectively) contain one ruthenium porphyrin/heme binding site; the species are readily interconverted using dithionite for reduction and bromine for oxidation. RuMb b...
متن کاملCharacterization of a Rh(III) porphyrin-CO complex: its structure and reactivity with an electron acceptor.
To analyse the electrocatalytic oxidation of carbon monoxide by Rh porphyrins, we isolated a CO-adduct of Rh octaethylporphyrin, and examined its properties and reactivity by IR, NMR, and X-ray crystallographic analyses. The results indicate that the CO adduct of Rh octaethylporphyrin is vulnerable to nucleophilic attack by H2O. The CO-adduct was easily oxidized by an electron acceptor (1,4-nap...
متن کاملExtraction - Spectrophotometric Determination of Palladium with Tetrabutyl Ammonium Iodide
A sensitive and selective extraction - spectrophotometric method for the determination of trace amounts of palladium is reported. The method is based on quantitative extraction of brownish tetrabutylammoium tetraiodopalladium (II) ion pair into a small valume of chloroform at pH 1.3-12.0, followed by spectrophotometric measurements. The Beer's law is obeyed over the range 0.02-1.09 <em...
متن کاملA Rapid Spectrophotometric 5me’l’i101> for the Determination of Methemoglobin and Carbonylhemoglobin in Blood
Little use has thus far been made of the near infra-red spectrum for the identification and determination of hemoglobin and its derivatives BJ means of infra-red photography Eggert (1) established the transparency of carbon monoxide-saturated blood and used this property for the qualitative detection of carbon monoxide poisoning.. Eggert’s ‘observations were extended and placed on a more quanti...