Silicon Selective Non-Doped Hydrogen Atmosphere Flame Ionization Detector for Gas Chromatography

نویسنده

  • M. A. Osman
چکیده

A commercial flame ionization detector was converted to a gas chromatographic detector selective for silicon-containing compounds by simply interchanging the oxygen and hydrogen inlets so that the flame burned in a hydrogen atmosphere. The optimal configuration of various detector geometries was found to be a narrow cylindrical tube with the collector electrode positioned more than 10 cm from the flame. This configuration eliminated peak tailing which is prevalent in other designs. Helium was shown to be the carrier gas of choice since nitrogen reduced the sensitivity of the detector to siliconcontaining compounds, but not lo hydrocarbon compounds. The calibration curve for tetraethylsilane proved to be linear for about three orders of magnitude with a minimum detectable amount of 4 ng and a selectivity over decane of 2600. This corresponds to a silicon to carbon selectivity better than 1 X lo4. The advantage of a silicon selective detector is demonstrated by comparing a chromatographic tracing of a mixture of n-alkanes and silylated n-alcohols to that of the same mixture obtained with a standard flame ionization detector. Three-microgram peaks of the silylated alcohols could easily be detected with the silicon selective detector while 3 qg of each alkane gave no response.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Hydrocarbons in a Hydrogen Atmosphere by Gas Chromatography with Flame Ionization

The ionization response of hydrocarbons In a hydrogen-atmosphere flame was compared to that of a normal flame ionization detector used in gas chromatography. Absolute response in the hydrogen-atmosphere flame lonizatlon detector (HAFID) was found to be two orders of magnitude less than that of the normal FID. This reduced response is attributed both to oxidation of hydrocarbons in the precombus...

متن کامل

Determination of 2-phenylethanol in Rose Water Using Dispersive Liquid-Liquid Microextraction with Gas Chromatography Flame Ionization Detection

A simple and rapid microextraction procedure based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-flame ionization detection (GC-FID) was developed for the extraction and analysis of 2-phenylethanol in rose water sample. In the proposed approach, carbon tetrachloride and ethanol were used as extraction and dispersive solvents, respectively. Some important pa...

متن کامل

Evaluation of the pulsed discharge helium ionization detector for the analysis of hydrogen and methane in breath.

Under the appropriate separation conditions the pulsed discharge helium ionization detector (PDHID) was used to detect hydrogen and methane separated from the matrix components of human breath samples. The sensitivity of this method is over an order of magnitude better than published methods using a flame ionization detector (FID) and a thermal conductivity detector (TCD), and has the further a...

متن کامل

Determination of valproic acid in human plasma using dispersive liquid-liquid microextraction followed by gas chromatography-flame ionization detection

Objective(s): Dispersive liquid-liquid microextraction coupled with gas chromatography (GC)-flame ionization detector was developed for the determination of valproic acid (VPA) in human plasma. Materials and Methods: Using a syringe, a mixture of suitable extraction solvent (40 µl chloroform) and disperser (1 ml acetone) was quickly added to 10 ml of diluted plasma sample containing VPA (pH, 1....

متن کامل

Simultaneous determination of urinary estriol, pregnanediol, and pregnanolone by gas-liquid chromatography.

A simplified method for following the urinary excretion of estriol, pregnanediol, and pregnanoloneduring the course of pregnancy is presented. The procedure has been used successfully in a large hospital laboratory. An important advantage is that the estrogen and progesterone metabolites are measured simultaneously, and separate extraction and gas-liquid chromatographyis not required. The urine...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002