Clinical value of multiplexed bead-based immunoassays for detection of autoantibodies to nuclear antigens.
نویسندگان
چکیده
The advent of multiplexed bead assays in recent years has introduced a new dimension of testing for complex diseases such as lupus, which can involve multiple autoantibodies. The ability to rapidly identify multiple autoantibodies, with high sensitivity and specificity in an automated fashion, is highly attractive. The aim of this study was to assess the performance and clinical value of multiplexed bead-based (AtheNA Multi-Lyte ANA-II test system) immunoassays both by comparing the results with those achieved by indirect fluorescent-antibody assay (IFA) or conventional enzyme immunoassays (EIAs) and by independent identification of autoantibodies in well-characterized samples. To achieve this goal, 984 samples were tested for seven analytes (SS/A, SS/B, Sm, RNP, Scl-70, double-stranded DNA [dsDNA], and centromere B) in both traditional and bead-based assays. The average concordance for the different analytes was 91%, ranging from 81% (dsDNA) to 97% (centromere B). The average relative specificity and sensitivity for the analytes were also high, 92% and 81%, respectively. An examination of 93 "normal controls" demonstrated a 7% false-positive rate, which was comparable to IFA. Percentages of different autoantibodies found in patients with a variety of disease conditions (34 with calcinosis, Raynaud's phenomenon, esophageal dysmotility, sclerodactyly, and telangiectasia; 41 with mixed connective tissue disease; 24 with scleroderma; and 35 with Sjogren's syndrome) were well within the range expected from each group. A scrutiny of results from AtheNA and EIA and Farr results for 185 systemic lupus erythematosus samples revealed comparable results by both methods, with the exception of SS/A and dsDNA, where AtheNA had a higher percentage of SS/A-positive results compared to EIA (51% versus 29%) and a lower percentage of dsDNA-positive results (18% versus 28% at a cutoff of 5 IU/ml).
منابع مشابه
Evaluation of multiplexed fluorescent microsphere immunoassay for detection of autoantibodies to nuclear antigens.
Antibodies to extractable nuclear antigens (ENA) are found in a variety of collagen vascular diseases. Determining the individual specificities of these antibodies is extremely useful in establishing the disease diagnosis and in some cases the prognosis. With a multiplexed fluorescent microsphere immunoassay, reactivity to five of the most diagnostically useful ENA was measured in 249 serum sam...
متن کاملPresent and future of the autoimmunity laboratory.
At present, autoimmunity laboratories are very dynamic owing to the constant and increasing availability of new tests, mainly due to the detection of new autoantibodies. The main characteristic of the autoimmunity laboratory and the one that differentiates it from other laboratories that use immunoassays as basic techniques is that it determines antibodies (autoantibodies) and not antigens. For...
متن کاملLimited reliability of the indirect immunofluorescence technique for the detection of anti-Rib-P antibodies
INTRODUCTION Autoantibodies to the ribosomal P proteins represent a highly specific marker for the diagnosis of systemic lupus erythematosus, where they have been associated with certain clinical manifestations. Historically, autoantibodies against ribosomal P proteins have been detected by indirect immunofluorescence, immunodiffusion, immunoblot, and other immunoassays. More recently, enzyme-l...
متن کاملMultiplexed Immunoassays
Immunoassay has been widely used for quantification of proteins and small molecules in medical diagnostics, proteomics, drug discovery, and various biological research.1 ELISA (Enzyme-Linked ImmunoSorbant Assay) is the most commonly used immunoassay format.2 Traditional ELISA assays used in clinical settings are laborious and expensive and often consume large quantities of reagents and patient ...
متن کاملµFBI: A Microfluidic Bead-Based Immunoassay for Multiplexed Detection of Proteins from a µL Sample Volume
BACKGROUND Over the last ten years, miniaturized multiplexed immunoassays have become robust, reliable research tools that enable researchers to simultaneously determine a multitude of parameters. Among the numerous analytical protein arrays available, bead-based assay systems have evolved into a key technology that enables the quantitative protein profiling of biological samples whilst requiri...