Metal sensitivity causing loosened joint prostheses.
نویسندگان
چکیده
Metal sensitivity, as measured by an in-vitro assay on peripheral blood lymphocytes, was evaluated in patients with failed joint prostheses. Lymphocyte transformation to chromium, cobalt, and nickel was measured in 24 patients having revision surgery for a painful or loose prosthesis and compared with that in 11 patients who had a successful hip prothesis in situ for at least 2 years previously. A positive response (lymphocyte stimulation index greater than 3) to at least one of the metals was found in 71% of the revision group compared to 9% of controls (P < 0.01). The positive correlation between prosthesis failure and in-vitro metal sensitivity suggests that cell-mediated immunity to metals to metals may play a role in prosthesis failure. Furthermore, this simple in-vitro test may provide the basis of a useful diagnostic test for an often difficult clinical problem.
منابع مشابه
Necrobiosis and T-lymphocyte infiltration in retrieved aseptically loosened metal-on-polyethylene arthroplasties
BACKGROUND AND PURPOSE Soft tissue necrobiosis and T-lymphocyte infiltration within the periprosthetic soft tissue have been linked to a suggested hypersensitivity reaction of the delayed-type following the metal-on-metal arthroplasty. While we observed both synovial necrobiosis and lymphocyte infiltrates in synovial tissues with failed metal-on-polyethylene prostheses, we hypothesized that bot...
متن کاملFive-year results of the ASR XL Acetabular System and the ASR Hip Resurfacing System: an analysis from the Australian Orthopaedic Association National Joint Replacement Registry.
BACKGROUND Articular Surface Replacement (ASR) hip prostheses, which have metal-on-metal bearing surfaces, were manufactured by DePuy Orthopaedics (Warsaw, Indiana) for use in both conventional total hip arthroplasty and hip resurfacing. Both the ASR XL Acetabular System and the ASR Hip Resurfacing System were recently recalled worldwide by the manufacturer. This report summarizes an analysis b...
متن کاملComplications Related to Metal-on-Metal Articulation in Trapeziometacarpal Joint Total Joint Arthroplasty
Adverse reactions to metal-on-metal (MoM) prostheses are well known from total hip joint resurfacing arthroplasty with elevated serum chrome or cobalt, pain and pseudo tumor formation. It may, however, also be seen after total joint replacement of the trapeziometacarpal joint using MoM articulation, and we present two cases of failure of MoM prostheses due to elevated metal-serum levels in one ...
متن کاملKnee replacement: a clinical review.
THE first successful knee arthroplasty was reported in 1861, but from then until the 1940s arthroplasty of the knee was of the interposition type using either autogenous tissue or a foreign non-metallic material between the joint surfaces. Results of this operation were at best poor and unpredictable when compared to arthrodesis, the alternative procedure for degenerative arthritis. Arthrodesis...
متن کاملMetal sensitivities and orthopaedic implants revisited: the potential for metal allergy with the new metal-on-metal joint prostheses.
The potential of metal-containing orthopaedic prostheses to induce problems through metal allergy taxes dermatologists and orthopaedic surgeons alike. Metal-on-plastic joint replacements are not thought to induce metal allergy but wear products, principally polypropylene particles, produce a foreign body reaction in bone and may lead to aseptic loosening of the joint. Orthopaedic surgeons are i...