Innovative Methodology High-Resolution Three-Dimensional Microelectrode Brain Mapping Using Stereo Microfocal X-ray Imaging

نویسندگان

  • David D. Cox
  • Alexander M. Papanastassiou
  • Daniel Oreper
  • Benjamin B. Andken
  • James J. DiCarlo
چکیده

Cox DD, Papanastassiou AM, Oreper D, Andken BB, DiCarlo JJ. High-resolution three-dimensional microelectrode brain mapping using stereo microfocal X-ray imaging. J Neurophysiol 100: 2966–2976, 2008. First published September 24, 2008; doi:10.1152/jn.90672.2008. Much of our knowledge of brain function has been gleaned from studies using microelectrodes to characterize the response properties of individual neurons in vivo. However, because it is difficult to accurately determine the location of a microelectrode tip within the brain, it is impossible to systematically map the fine three-dimensional spatial organization of many brain areas, especially in deep structures. Here, we present a practical method based on digital stereo microfocal X-ray imaging that makes it possible to estimate the three-dimensional position of each and every microelectrode recording site in “real time” during experimental sessions. We determined the system’s ex vivo localization accuracy to be better than 50 !m, and we show how we have used this method to coregister hundreds of deep-brain microelectrode recordings in monkeys to a common frame of reference with median error of !150 !m. We further show how we can coregister those sites with magnetic resonance images (MRIs), allowing for comparison with anatomy, and laying the groundwork for more detailed electrophysiology/functional MRI comparison. Minimally, this method allows one to marry the single-cell specificity of microelectrode recording with the spatial mapping abilities of imaging techniques; furthermore, it has the potential of yielding fundamentally new kinds of high-resolution maps of brain function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution three-dimensional microelectrode brain mapping using stereo microfocal X-ray imaging.

Much of our knowledge of brain function has been gleaned from studies using microelectrodes to characterize the response properties of individual neurons in vivo. However, because it is difficult to accurately determine the location of a microelectrode tip within the brain, it is impossible to systematically map the fine three-dimensional spatial organization of many brain areas, especially in ...

متن کامل

High Resolution In-Vivo Electrode Localization Using Microfocal X-Rays

Neuroscientists lack the ability to perform in-vivo electrode localization with high accuracy, especially in deep brain structures. The design, implementation and testing of a microfocal x-ray stereo system that offers an efficient, accurate, and relatively low-cost solution this localization problem is presented. The results indicate the ability to localize a targets to within ~50 microns, in ...

متن کامل

Innovative Methodology Three-dimensional imaging and morphometric analysis of alveolar tissue from microfocal X-ray-computed tomography

Litzlbauer, Horst Detlef, Christoph Neuhaeuser, Alexander Moell, Susanne Greschus, Andreas Breithecker, Folker Ernst Franke, Wolfgang Kummer, and Wigbert Stephan Rau. Threedimensional imaging and morphometric analysis of alveolar tissue from microfocal X-ray-computed tomography. Am J Physiol Lung Cell Mol Physiol 291: L535–L545, 2006. First published May 5, 2006; doi:10.1152/ajplung.00088.2005....

متن کامل

Three-dimensional visualization and morphometry of small airways from microfocal X-ray computed tomography.

Physiological morphometry is a critical factor in the flow dynamics in small airways. In this study, we visualized and analyzed the three-dimensional structure of the small airways without dehydration and fixation. We developed a two-step method to visualize small airways in detail by staining the lung tissue with a radiopaque solution and then visualizing the tissue with a cone-beam microfocal...

متن کامل

Quantifying Mesoscale Neuroanatomy Using X-Ray Microtomography

Methods for resolving the three-dimensional (3D) microstructure of the brain typically start by thinly slicing and staining the brain, followed by imaging numerous individual sections with visible light photons or electrons. In contrast, X-rays can be used to image thick samples, providing a rapid approach for producing large 3D brain maps without sectioning. Here we demonstrate the use of sync...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008