Preload dependence of new Doppler techniques limits their utility for left ventricular diastolic function assessment in hemodialysis patients.

نویسندگان

  • Eric H Y Ie
  • Wim B Vletter
  • Folkert J ten Cate
  • Robert W Nette
  • Willem Weimar
  • Jos R T C Roelandt
  • Robert Zietse
چکیده

Left ventricular (LV) hypertrophy leads to diastolic dysfunction. Standard Doppler transmitral and pulmonary vein (PV) flow velocity measurements are preload dependent. New techniques such as mitral annulus velocity by Doppler tissue imaging (DTI) and LV inflow propagation velocity measured from color M-mode have been proposed as relatively preload-independent measurements of diastolic function. These parameters were studied before and after hemodialysis (HD) with ultrafiltration to test their potential advantage for LV diastolic function assessment in HD patients. Ten patients (seven with LV hypertrophy) underwent Doppler echocardiography 1 h before, 1 h after, and 1 d after HD. Early (E) and atrial (A) peak transmitral flow velocities, peak PV systolic (s) and diastolic (d) flow velocities, peak e and a mitral annulus velocities in DTI, and early diastolic LV flow propagation velocity (V(p)) were measured. In all patients, the E/A ratio after HD (0.54; 0.37 to 1.02) was lower (P < 0.01) than before HD (0.77; 0.60 to 1.34). E decreased (P < 0.01), whereas A did not. PV s/d after HD (2.15; 1.08 to 3.90) was higher (P < 0.01) than before HD (1.80; 1.25 to 2.68). Tissue e/a after HD (0.40; 0.26 to 0.96) was lower (P < 0.01) than before HD (0.56; 0.40 to 1.05). Tissue e decreased (P < 0.02), whereas a did not. V(p) after HD (30 cm/s; 16 to 47 cm/s) was lower (P < 0.01) than before HD (45 cm/s; 32 to 60 cm/s). Twenty-four hours after the initial measurements values for E/A (0.59; 0.37 to 1.23), PV s/d (1.85; 1.07 to 3.38), e/a (0.41; 0.27 to 1.06), and V(p) (28 cm/s; 23 to 33 cm/s) were similar as those taken 1 h after HD. It is concluded that, even when using the newer Doppler techniques DTI and color M-mode, pseudonormalization, which was due to volume overload before HD, resulted in underestimation of the degree of diastolic dysfunction. Therefore, the advantage of these techniques over conventional parameters for the assessment of LV diastolic function in HD patients is limited. Assessment of LV diastolic function should not be performed shortly before HD, and its time relation to HD is essential.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی اثر کاهش حجم بر روی پارامترهای دیاستولیک اکو کاردیوگرافی در بیماران همودیالیزی

Background: Cardiovascular problems including arterial hypertension, coronary artery diseases, congestive heart failure are prevalent among chronic hemodialyzed patients. Ultrafiltration of hemodialyzed patient's serum, which culminating in intravascular volume reduction, is frequently used during hemodialysis. One of the restrictions of the echocardiographic evaluation of the diastolic heart f...

متن کامل

Influence of Preload Reduction on Left Ventricular Diastolic Function in Hemodialysis Patients with Left Ventricular Hypertrophy

Objectives: The purpose of this study was to assess how the preload reduction a#ects left ventricular LV diastolic function in hemodialysis patients with LV hypertrophy. Methods: Subjects included 14 patients with LV hypertrophy receiving hemodialysis. The subjects underwent echocardiographic and pulsed Doppler examinations before and after hemodialysis, and the data were analyzed to determine ...

متن کامل

Increase in serum ionized calcium during diffusive dialysis does not affect left ventricular diastolic function.

An increase in serum Ca2+ during hemodialysis (HD) may lead to impaired left ventricular (LV) relaxation. Since LV diastolic function assessment in dialysis patients is hampered by preload dependence of Doppler measurements, we tested the effect of HD without ultrafiltration (UF) on these measurements. Transmitral E and A velocities, and mitral annulus e and a velocities were measured in 10 pat...

متن کامل

LEFT VENTRICULAR DIASTOLIC ABNORMALITIES IN β-THALASSEMIA MAJOR WITH NORMAL SYSTOLIC FUNCTION

In order to identify left ventricular diastolic function in patients with betathalassemia major and normal systolic function by noninvasive M-mode and Doppler echocardiography, an analytic study was designed in a university hospital in Sari. We have studied 44 patients (23 men and 21 women), mean age 15.48±2.16 (range 12 to 20) and 43 age and sex matched control subjects. Peak flow velocit...

متن کامل

[Influence of preload reduction on Tei index and other Doppler echocardiographic parameters of left ventricular function].

OBJECTIVE To assess the influence of preload reduction by hemodialysis on Doppler Tei Index of myocardial performance and other parameters of cardiac function. METHODS The Tei index and left ventricular (LV) systolic and diastolic function parameters were estimated, before and after a single hemodialysis session. Only subjects who were in sinus rhythm, without history of coronary artery disea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Society of Nephrology : JASN

دوره 14 7  شماره 

صفحات  -

تاریخ انتشار 2003