OBJECTIVE The overarching goal of this study was to examine the use of triaxial accelerometers in measuring upper-extremity motions to monitor upper-extremity-exercise compliance. There were multiple questions investigated, but the primary objective was to investigate the correlation between visually observed arm motions and triaxial accelerometer activity counts to establish fundamental activity counts for the upper extremity. STUDY DESIGN Cross-sectional, basic research. SETTING Clinical laboratory. PARTICIPANTS Thirty healthy individuals age 26 ± 6 y, body mass 24 ± 3 kg, and height 1.68 ± 0.09 m volunteered. INTERVENTION Participants performed 3 series of tasks: activities of daily living (ADLs), rehabilitation exercises, and passive shoulder range of motion at 5 specific velocities on an isokinetic dynamometer while wearing an accelerometer on each wrist. Participants performed exercises with their dominant arm to examine differences between sides. A researcher visually counted all arm motions to correlate counts with physical activity counts provided by the accelerometer. MAIN OUTCOME MEASURE Physical activity counts derived from the accelerometer and visually observed activity counts recorded from a single investigator. RESULTS There was a strong positive correlation (r = .93, P < .01) between accelerometer physical activity counts and visual activity counts for all ADLs. Accelerometers activity counts demonstrated side-to-side difference for all ADLs (P < .001) and 5 of the 7 rehabilitation activities (P < .003). All velocities tested on the isokinetic dynamometer were shown to be significantly different from each other (P < .001). CONCLUSION There is a linear relationship between arm motions counted visually and the physical activity counts generated by an accelerometer, indicating that arm motions could be potentially accounted for if monitoring arm usage. The accelerometers can detect differences in relatively slow arm-movement velocities, which is critical if attempting to evaluate exercise compliance during early phases of shoulder rehabilitation. These results provide fundamental information that indicates that triaxial accelerometers have the potential to objectively monitor and measure arm activities during rehabilitation and ADLs.
منابع مشابه
Predictors of Upper-Extremity Physical Function in Older Adults
Background: Little is known about the influence of habitual participation in physical exercise and diet on upper-extremity physical function in older adults. To assess the relationship of general physical exercise and diet to upper-extremity physical function and pain intensity in older adults. Methods: A cohort of 111 patients 50 or older completed a sociodemographic survey, the Rapid Asse...
متن کاملComparison of Upper Extremity Motor Recovery of Stroke Patients with Actual Physical Activity in Their Daily Lives Measured with Accelerometers
[Purpose] This study compared the upper extremity recovery of stroke patients with the amount of their upper extremity use in real life as measured by accelerometers. [Subjects] Forty inpatients who had had a stroke were recruited. [Methods] The subjects were divided into two groups by the Fugl-Meyer Assessment of Motor Function (FMA) score, a moderately recovered group and a well recovered gro...
متن کاملSensitivity of the accelerometer as a measurement tool for upper extremity movement by stroke patients: a comparison with the action research arm test
[Purpose] This study investigated the sensitivity of an accelerometer in a comparison with the Action Research Arm Test (ARAT). [Subjects] Fifteen stroke patients participated in this study. [Methods] Subjects wore accelerometers on both wrists and performed the ARAT items. We then compared the data measured by the accelerometer with that of the ARAT. [Results] ARAT scores were higher on the no...
متن کاملTest-retest reliability of Motricity Index strength assessments for lower extremity in post stroke hemiparesis
Background: The Motricity Index was used to measure strength in upper and lower extremities after stroke. The weighted score based on the ordinal 6 point scale of Medical Research Council was used to measure maximal isometric muscle strength. There is dearth of articles dealing with the reliability of this method. Therefore, the aim of this study was to determine the test retest reliability o...
متن کاملThe Test-Retest Reliability and Minimal Detectable Change of the Fugl-Meyer Assessment of the Upper Extremity and 9-Hole Pegboard Test in Individuals With Subacute Stroke
Purpose: The first step to manage motor impairment of upper limb in patients with subacute stroke is having an accurate assessment tool. The Fugl-Meyer assessment of upper extremity and 9-hole pegboard test are used to evaluate motor function and hand dexterity in stroke survivals. The present study aimed to investigate the test-retest reliability and minimal detectable change (MDC) in these tw...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of sport rehabilitation
دوره 24 3 شماره
صفحات -
تاریخ انتشار 2015