Delineation of Margins for the Planning Target Volume (PTV) for Image-Guided Radiotherapy (IGRT) of Gastric Cancer Based on Intrafraction Motion
نویسندگان
چکیده
Background: Application of the image-guided radiotherapy (IGRT) system for gastric cancer involving daily verification of patient positioning on the treatment machine allows minimisation of geometrical errors as a consequence of intra- and inter-fraction motion. The purpose of this study was to define the intrafraction motion in gastric cancer patients during a treatment session based on the IGRT system and designation of margins around the clinical target volume CTV (internal target volume ITV) necessary to delineate the planning target volume (PTV). Methods: Twenty gastric cancer patients were analysed. The total radiation dose for each was 45Gy in 25 fractions within 5 weeks. The margins for the PTV were calculated according to van Herk (2004), Stroom and Heijmen (2002) and the International Commission on Radiation Units and Measurements (ICRU) Report 62 formulas based on craniocaudal (Y axis), laterolateral (X axis) and anteroposterior (Z axis) shifts. Results: Delineated margins for the PTV in gastric cancer with the three formulas applied were respectively 0.2, 0.2, and 0.2cm in the lateral plane, 0.3, 0.3, and 0.3cm in the craniocaudal plane and 0.3, 0.3, and 0.2cm in the anteroposterior plane. Conclusions: Recommended margins for the PTV in gastric cancer calculated in this study based on intrafraction motion are 0.3cm, 0.2cm and 0.3cm in the craniocaudal, lateral and anterioposterior directions, respectively. Use of the IGRT system corrects for the motions between factions and allows reduction in ITV-PTV margins. The main advantage of the smaller margins in comparison to the non-IGRT radiotherapy is a reduction in the probability of radiation complications.
منابع مشابه
Inter- and intrafraction uncertainty in prostate bed image-guided radiotherapy.
PURPOSE The goals of this study were to measure inter- and intrafraction setup error and prostate bed motion (PBM) in patients undergoing post-prostatectomy image-guided radiotherapy (IGRT) and to propose appropriate population-based three-dimensional clinical target volume to planning target volume (CTV-PTV) margins in both non-IGRT and IGRT scenarios. METHODS AND MATERIALS In this prospecti...
متن کاملGeographical miss of the prostate during image‐guided radiotherapy with a 6‐mm posterior expansion margin
INTRODUCTION Our department commonly uses a planning target volume (PTV) expansion of 6 mm posterior and 1 cm in all other directions when treating prostate cancer patients with image-guided radiotherapy (IGRT). This study aimed to test the adequacy of this PTV expansion by assessing geographical miss of the prostate on post-treatment cone-beam CT (CBCT) and identify those at risk of geographic...
متن کاملThe effect of image-guided radiation therapy on the margin between the clinical target volume and planning target volume in lung cancer
IntroductionThis study aimed to evaluate the effect of image-guided radiation therapy (IGRT) on the margin between the clinical target volume (CTV) and planning target volume (PTV) in lung cancer. MethodsThe CTV and PTV margin were determined in three dimensions by four radiation oncologists using a standard method in 10 lung cancer patients, and compared to consensus values. Transfer error was...
متن کاملPTV margin definition in hypofractionated IGRT of localized prostate cancer using cone beam CT and orthogonal image pairs with fiducial markers
PURPOSE To evaluate PTV margins for hypofractionated IGRT of prostate comparing kV/kV imaging or CBCT. PATIENTS AND METHODS Between 2009 and 2012, 20 patients with low- (LR), intermediate- (IR) and high-risk (HR) prostate cancer were treated with VMAT in supine position with fiducial markers (FM), endorectal balloon (ERB) and full bladder. CBCT's and kV/kV imaging were performed before and ad...
متن کاملThe Utility of Positron Emission Tomography in the Treatment Planning of Image-Guided Radiotherapy for Non-Small Cell Lung Cancer
In the thorax, the extent of tumor may be more accurately defined with the addition of (18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET) to computed tomography (CT). This led to the increased utility of FDG-PET or PET/CT in the treatment planning of radiotherapy for non-small cell lung cancer (NSCLC). The inclusion of FDG-PET information in target volume delineation not only imp...
متن کامل