YIM-O20. Standardization and performance of cone beam ct scan for the evaluation of linear scleroderma of the face
نویسندگان
چکیده
Introduction Up to now, standardized and validated methods for monitoring linear scleroderma of the face are still lacking. Therefore, it is difficult to assess, in these patients, the disease progression both for therapeutic purposes and maxillofacial surgery procedures. The Cone Beam Computed Tomography (CBCT) is an imaging technique that has good sensitivity for both soft and the bony tissues, is fast to be performed, does not require sedation and the irradiation is 50 times lower than traditional CT scan.
منابع مشابه
Evaluation of the gray level in CBCT systems and its relationship with HU in CT Scanners
Introduction: Cone-beam CT (CBCT) is an imaging system which offers three-dimensional (3D), multiplanar images and has many advantages over computed tomography (CT) including shorter acquisition times for the resolution desired in dentistry, lower radiation dose to the patient, reasonable price and higher spatial resolution but CBCT scanners are unable to display actual Hounsf...
متن کاملUsability assessment of cone beam computed tomography with a full-fan mode bowtie filter compared to that with a half-fan mode bowtie filter
Background: In intensity modulated radiation therapy, cone beam computed tomography (CT) has been used to evaluate patients prior to treatment. This study conducted a comparative evaluation of the image reconstruction ability of the clinically used half-fan bowtie filter and the full-fan bowtie filter. Materals and Methods: A CT simulation marker was inserted inside a human phantom, and the pel...
متن کاملEvaluation of Factors Affecting Absorbed Dose, Optimization Methods and Patient Dose Reduction in Dental Cone Beam CT (CBCT)
Introduction: Nowadays the use of cone beam computed tomography in dental imaging is increasing, although this method has a much lower dose than conventional CT scans, it delivers a higher dose than the panoramic and periapical patients therefore, , the aim of this study was to investigate the factors affecting the patients' dose in dental CBCTs and methods of optimizing and reducing the patien...
متن کاملCone Beam CT Evaluation of the Bony Changes in the Temporomandibular Joint and the Association with the Clinical Symptoms of Temporomandibular Joint Disorders
Introduction: Temporomandibular joint (TMJ) disorders are among the most prevalent abnormalities of the jaw, which affect the masticatory system, including the muscles, TMJ, and tendons. Clinical examination alone cannot determine the cause of temporomandibular disorder (TMD). In most cases, the cause of TMD and a proper treatment plan are determined based on imaging modalities. The present stu...
متن کاملMethods to evaluate the performance of kilovoltage cone-beam computed tomography in the three-dimensional reconstruction space
Background: Cone-beam computed tomography (CBCT) scanners for image-guided radiotherapy are in clinical use today, but there has been no consensus on uniform acceptance to verify the CBCT image quality yet. The present work proposed new methods to fully evaluate the performance of CBCT in its three-dimensional (3D) reconstruction space. Materials and Methods: Compared to the traditional methods...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2014