Radiofrequency cannula with active tip radio-opaque marker: image analysis for facet, gray ramus, and dorsal root ganglion techniques.

نویسنده

  • Joseph F Jasper
چکیده

BACKGROUND Radiofrequency neurolysis is a common technique used in the treatment of chronic pain, particularly facet (zygapophyseal joint) arthralgia. A needle-like cannula is insulated except for the exposed active tip, which is positioned as parallel and adjacent as possible to the targeted nerve branch. Via an inserted probe connected to a radiofrequency generator, energy flowing from the tip of the cannula creates a heat lesion in the 80 - 85 degree Celsius range mostly about the length of the exposed active tip and in proportion to the diameter of the probe. The common active tip lengths used for neurolysis are 5mm or 10mm. The cannulae are FDA approved. The manufacturer advises physicians not to bend or otherwise modify a cannula prior to use. The cannulae are available straight or bent, sharp and blunt. The technique is guided under C-arm fluoroscopy. X-rays passing through the patient demonstrate in 2 dimensions the projected relative radio-opaque bony landmarks and the metallic cannula. Most currently available cannulae are uniform in their radio-opacity from tip to hub. The physician must make an educated guess as to the portion of the cannula that will be making the lesion in relationship to the bony landmark. OBJECTIVE A new radiofrequency cannula with a radio-opaque marker (ROC) delineates the proximal end of the active tip. The cannula was used in a phantom model. Images were reproduced with explanation of the potential advantage of the new device. RESULT The marker on the new cannula was visible and did help delineate the active tip as well as its orientation. It was also helpful in making sequential lesions at the same nerve using a "tip to tail" repositioning technique. CONCLUSION The ROC did represent an improvement over standard cannulae to optimize visualization of cannula and thus lesion placement using a phantom model. The applications described were only for conventional or "hot" RF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Endoscopically Guided Foraminal and Dorsal Rhizotomy for Chronic Axial Back Pain Based on Cadaver and Endoscopically Visualized Anatomic Study

BACKGROUND Conventional fluoroscopically guided continuous radiofrequency (CRF) and pulsed Radiofrequency (PRF) lesioning of the medial branch, dorsal ramus, a standard technique to treat facet pain, is compared to an endoscopic visually guided technique. The endoscopic technique (Figure 1) is designed to ablate a larger area of the transverse process where the medial branch crosses to innervat...

متن کامل

Pulsed and continuous radiofrequency current adjacent to the cervical dorsal root ganglion of the rat induces late cellular activity in the dorsal horn.

BACKGROUND Pulsed radiofrequency treatment has recently been described as a non-neurodestructive or minimally neurodestructive alternative to radiofrequency heat lesions. In clinical practice long-lasting results of pulsed radiofrequency treatment adjacent to the cervical dorsal root ganglion for the management of chronic radicular spinal pain have been reported without neurologic complications...

متن کامل

Medial branch blocks and facet joint injections as predictors of successful radiofrequency ablation

Zygapophyseal (z) joints (or facet joints) are a potential source of pain in nearly 15-45% of patients suffering from chronic spinal pain. There are no clinical features or imaging techniques pathognomonic for z-joint pain. Blockade of the medial branch of the spinal nerve primary posterior ramus, using fluoroscopic guidance to ensure positioning of the needle tip and low volumes of local anest...

متن کامل

Randomised controlled trial of cervical radiofrequency lesions as a treatment for cervicogenic headache [ISRCTN07444684]

BACKGROUND Cervicogenic headache (CEH) is a unilateral headache localised in the neck or occipital region, projecting to the frontal and temporal regions. Since the pathogenesis of this syndrome appears to have an anatomical basis in the cervical region, several surgical procedures aimed at reducing the nociceptive input on the cervical level, have been tested. We developed a sequence of variou...

متن کامل

The surgical anatomy of lumbar medial branch neurotomy (facet denervation).

OBJECTIVE To demonstrate the validity of placing electrodes parallel to the target nerve in lumbar radiofrequency neurotomy. DESIGN Previous data on the anatomy of the lumbar dorsal rami were reviewed and a demonstration cadaver was prepared. Under direct vision, electrodes were placed on, and parallel to, the L4 medial branch and the L5 dorsal ramus. Photographs were taken to record the plac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pain physician

دوره 11 6  شماره 

صفحات  -

تاریخ انتشار 2008