Reliability of MR perfusion-weighted and diffusion-weighted imaging mismatch measurement methods.

نویسندگان

  • M Luby
  • S Warach
چکیده

BACKGROUND AND PURPOSE We investigated 2 methods of measuring MR imaging perfusion-diffusion mismatch to determine whether reliability is improved by direct measurement on a single, blended map. MATERIALS AND METHODS Image software was used for measurement of lesion volumes from diffusion-weighted images (DWI) and mean transit time (MTT) calculated from perfusion-weighted (PWI) images on 64 patients with acute stroke. For the first method, the DWI and MTT lesions were measured separately. For the second method, the mismatch volume was measured directly on the blended images created from the registered DWI and MTT images. RESULTS Test-retest agreement was 100% and 97% for the separate and blended methods using mismatch cutoffs of 20% or more versus less than 20%. There were no significant differences in the mismatch statistics between the methods. CONCLUSIONS Mismatch volumes by a single reader can provide highly reliable and consistent results even when separately measuring DWI and MTT lesions. Propagation of measurement error was not demonstrated, and the methods were statistically comparable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid assessment of perfusion-diffusion mismatch.

BACKGROUND AND PURPOSE For MR perfusion-diffusion (PWI-DWI) mismatch to become routine in thrombolysis patient selection, rapid and reliable assessment tools are required. We examined interrater variability in PWI/DWI volume measurements and developed a rapid assessment tool based on the Alberta Stroke Program Early CT Scores (ASPECTS) system. METHODS DWI and PWI were performed in 35 patients...

متن کامل

Reliability of assessing percentage of diffusion-perfusion mismatch.

BACKGROUND AND PURPOSE Emergent neurovascular imaging holds promise in identifying new and optimum target populations for thrombolysis in stroke. Recent research has focused on patients with diffusion-weighted MRI (DWI)-perfusion-weighted MRI (PWI) mismatch as a marker of tissue at risk of infarction and a means to select the most suitable candidates for thrombolysis. The present study sought t...

متن کامل

An Explanation for Infarct Growth Without Perfusion-Weighted Imaging/Diffusion-Weighted Imaging Mismatch in Patients With Acute Ischemic Stroke

Background and Purpose—In ischemic stroke, MR perfusion-weighted imaging (PWI) and diffusion-weighted imaging (DWI) mismatch represents tissue at risk for infarction. Infarct growth should only take place in the presence of mismatch, although there have been reports of this occurring. We hypothesized that this observation may be attributable to the presence of undetected “hidden mismatch,” whic...

متن کامل

Comparison of computed tomography perfusion and magnetic resonance imaging perfusion-diffusion mismatch in ischemic stroke.

BACKGROUND AND PURPOSE Perfusion imaging has the potential to select patients most likely to respond to thrombolysis. We tested the correspondence of computed tomography perfusion (CTP)-derived mismatch with contemporaneous perfusion-diffusion magnetic resonance imaging (MRI). METHODS Acute ischemic stroke patients 3 to 6 hours after onset had CTP and perfusion-diffusion MRI within 1 hour, be...

متن کامل

The hidden mismatch: an explanation for infarct growth without perfusion-weighted imaging/diffusion-weighted imaging mismatch in patients with acute ischemic stroke.

BACKGROUND AND PURPOSE In ischemic stroke, MR perfusion-weighted imaging (PWI) and diffusion-weighted imaging (DWI) mismatch represents tissue at risk for infarction. Infarct growth should only take place in the presence of mismatch, although there have been reports of this occurring. We hypothesized that this observation may be attributable to the presence of undetected "hidden mismatch," whic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 28 9  شماره 

صفحات  -

تاریخ انتشار 2007