Calculation of the confidence bounds for the fraction nonconforming of normal populations of measurements in clinical laboratory medicine

نویسنده

  • Aristides T. Hatjimihail
چکیده

The fraction nonconforming is a key quality measure used in statistical quality control design in clinical laboratory medicine. The confidence bounds of normal populations of measurements for the fraction nonconforming each of the lower and upper quality specification limits when both the random and the systematic error are unknown can be calculated using the noncentral t-distribution, as it is described in detail and illustrated with examples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Exact maximum coverage probabilities of confidence intervals with increasing bounds for Poisson distribution mean

 ‎A Poisson distribution is well used as a standard model for analyzing count data‎. ‎So the Poisson distribution parameter estimation is widely applied in practice‎. ‎Providing accurate confidence intervals for the discrete distribution parameters is very difficult‎. ‎So far‎, ‎many asymptotic confidence intervals for the mean of Poisson distribution is provided‎. ‎It is known that the coverag...

متن کامل

Evaluation of the accuracy of calculated dose with the EPL and ETAR algorithms using thorax CIRS phantom.

Introduction: Each treatment planning algorithm has some errors in dose calculation. Particularly these errors are more pronounced in the heterogeneous regions. It is recommended for each set of radiation data and algorithm subtle deliberation done regarding dose calculation accuracy. Knowing the amount of error in dose calculation will result in a fairly accurate estimate of t...

متن کامل

Normal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT

  Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...

متن کامل

Calculation of 99mTc-DTPA transit times in normal kidney [Persian]

Introduction: Renal dynamic study is a well-established and popular test in routine practice of nuclear medicine. The test is non-invasive, rapid and unique in evaluation of the kidney function. In despite of its clinical values, the parameters derived from renogram are physiologically meaningless. That is due to the fact that renogram is not the true kidney function. From mathematical po...

متن کامل

Assessment of Dose Calculation Accuracy of TiGRT Treatment Planning System for Physical Wedged fields in Radiotherapy

Introduction Wedge modifiers are commonly applied in external beam radiotherapy to change the dose distribution corresponding to the body contour and to obtain a uniform dose distribution within the target volume. Since the radiation dose delivered to the target must be within ±5% of the prescribed dose, accurate dose calculation by a treatment planning system (TPS) is important. The objective ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • CoRR

دوره abs/1506.00571  شماره 

صفحات  -

تاریخ انتشار 2015