Outcomes with various drug eluting or bare metal stents in patients with diabetes mellitus: mixed treatment comparison analysis of 22 844 patient years of follow-up from randomised trials
نویسندگان
چکیده
OBJECTIVES To evaluate the efficacy and safety of currently used drug eluting stents compared with each other and compared with bare metal stents in patients with diabetes. DESIGN Mixed treatment comparison meta-analysis. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and CENTRAL were searched for randomised clinical trials, until April 2012, of four durable polymer drug eluting stents (sirolimus eluting stents, paclitaxel eluting stents, everolimus eluting stents, and zotarolimus eluting stents) compared with each other or with bare metal stents for the treatment of de novo coronary lesions and enrolling at least 50 patients with diabetes. PRIMARY OUTCOMES Efficacy (target vessel revascularisation) and safety (death, myocardial infarction, stent thrombosis). RESULTS From 42 trials with 22,844 patient years of follow-up, when compared with bare metal stents (reference rate ratio 1) all of the currently used drug eluting stents were associated with a significant reduction in target vessel revascularisation (37% to 69%), though the efficacy varied with the type of stent (everolimus eluting stents~sirolimus eluting stents>paclitaxel eluting stents~zotarolimus eluting stent>bare metal stents). There was about an 87% probability that everolimus eluting stents were the most efficacious compared with all others, though there were limited usable data for the zotarolimus eluting Resolute stent in patients with diabetes. Moreover, there was no increased risk of any safety outcome (including very late stent thrombosis) with any drug eluting stents compared with bare metal stents. There was about a 62% probability that the everolimus eluting stent was the safest stent for the outcome of "any" stent thrombosis. CONCLUSIONS Among patients with diabetes treated with coronary stents all currently available drug eluting stents were efficacious without compromising safety compared with bare metal stents. There were relative differences among the drug eluting stents, such that the everolimus eluting stent was the most efficacious and safe.
منابع مشابه
Effects of cobalt-chromium everolimus eluting stents or bare metal stent on fatal and non-fatal cardiovascular events: patient level meta-analysis
OBJECTIVES To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. DESIGN Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for ...
متن کاملINTERVENTIONAL CARDIOLOGY AND SURGERY Efficacy of drug eluting stents in patients with and without diabetes mellitus: indirect comparison of controlled trials
Objective: To examine whether polymer based coronary stents eluting sirolimus or paclitaxel are equally effective in patients with and without diabetes. Methods: Systematic review and meta-analysis by indirect comparison of randomised controlled trials comparing stents eluting sirolimus or paclitaxel with conventional bare metal stents. The overall study population and patients with and without...
متن کاملOutcomes with coronary artery bypass graft surgery versus percutaneous coronary intervention for patients with diabetes mellitus: can newer generation drug-eluting stents bridge the gap?
BACKGROUND Coronary artery bypass graft surgery (CABG) compared with percutaneous coronary intervention (PCI) reduces mortality in patients with diabetes mellitus. However, prior trials compared CABG with balloon angioplasty or older generation stents, and it is not known if the gap between CABG and PCI can be reduced by newer generation drug-eluting stents. METHODS AND RESULTS PUBMED/EMBASE/...
متن کاملEfficacy of drug eluting stents in patients with and without diabetes mellitus: indirect comparison of controlled trials.
OBJECTIVE To examine whether polymer based coronary stents eluting sirolimus or paclitaxel are equally effective in patients with and without diabetes. METHODS Systematic review and meta-analysis by indirect comparison of randomised controlled trials comparing stents eluting sirolimus or paclitaxel with conventional bare metal stents. The overall study population and patients with and without...
متن کاملBare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis
OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...
متن کامل