Analytical study of three cystatin C assays and their impact on cystatin C-based GFR-prediction equations.
نویسندگان
چکیده
BACKGROUND Cystatin C-based equations are used to estimate GFR. However, three cystatin C immunoassays are on the market. Difference in cystatin C assays could have strong consequences on the accuracy and precision of cystatin C-based equations. We have performed an analytical study of these three assays and studied potential differences between assays on the precision of cystatin C-based equations. METHODS We have studied imprecision, recovery, linearity and interferences of the three immunoassays (nephelometric assay from Siemens and turbidimetric assays from Dako and Gentian). The impact of differences in cystatin C assays has been studied for the equations published by Levey (Siemens assay) and Grubb (Dako assay). RESULTS Analytical performance of the Dako assay is slightly less high. For cystatin C values below 2.5 mg/L, no statistical difference is found between results given by the Dako and the Gentian assays. So, both assays can be used in the Grubb equation. Cystatin C results are different with the Siemens assay. The Levey equation, built with the Siemens assay, can only be used with cystatin C values measured with this assay. Using the Dako or Gentian assay results in the Levey equation can lead to differences in estimating GFR up to 6 mL/min/1.73 m2. Differences can reach 9.5 mL/min/1.73 m2 if the Siemens assay is used in the Grubb equation. CONCLUSION The Siemens and Gentian assays seem analytically more valid than the Dako assay for cystatin C determination. Differences in cystatin C assays can lead to significant differences in cystatin C-based equations. However, these differences seem less important than the differences observed with creatinine and creatinine-based equations.
منابع مشابه
بررسی ارتباط میزان فیلتراسیون گلومرولی (GFR) با عملکرد کبد در بیماران سیروز کبدی
Background and purpose: Serum creatinine and its derived formulae in estimating glomerular filtration rate is not accurate in cirrhotic patients because of decreased muscle mass and secretion and excretion functional impairment of liver. This study aimed at investigating the accuracy of serum cystatin C in determining GFR and examining the relationship between synthetic and excretory liver func...
متن کاملبررسی مقایسهای ارزش تشخیصی سیستاتین C و کراتینین سرمی در ارزیابی عملکرد کلیه پیوندی در بیماران گیرنده کلیه در دوران اولیه پس از پیوند
Background &Aim: Early detection of decreasing glomerular filtration rate (GFR) is critical to prevent graft rejection in post-transplantation period. Serum creatinine has several drawbacks as a marker of GFR, so serum cystatin C has been proposed as an alternative GFR marker. Thus, we prospectively evaluated the diagnostic value of cystatin C measurements compared with serum creatinine in t...
متن کاملAssessing the Prediction Power of Plasma Neutrophil Gelatinase-Associated Lipocalin and Serum Cystatin C for Diagnosis Kidney Damage
Background & Objective: Chronic Kidney Disease (CKD) has been recognized as a serious public health threat. The early detection of kidney damage in CKD is a useful way to reduce the disease burden. This study aimed to determine the power of Neutrophil gelatinase-associated lipocalin (NGAL) and cystatin C (Cys-C) to predict the kidney damage in Iranian patients. Materials & Methods: This st...
متن کاملSERUM CYSTATIN C AS A NEW MARKER OF GLOMERULAR FILTRATION RATE (GFR)
Cystatin C is a 13 KD basic protein that is a member of the cystatin superfamily of cysteine protease inhibitors. The cystatin C gene seems to be a house keeping gene, which is compatible with a stable production rate of cystatin C by most cells. This protein is freely filtered through the glomerulus and almost completely reabsorbed and catabolized by proximal tubular cells. Because of the...
متن کاملCystatin C standardization decreases assay variation and improves assessment of glomerular filtration rate.
BACKGROUND Cystatin C is increasingly used in glomerular filtration rate (GFR) estimation equations. The dependence of cystatin C results upon the analytical method has been a major source of controversy. METHODS Cystatin C was measured with non-standardized turbidimetric Roche Generation 1 and standardized nephelometric Siemens assays in 3666 and additionally with standardized Roche Generati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinica chimica acta; international journal of clinical chemistry
دوره 398 1-2 شماره
صفحات -
تاریخ انتشار 2008