Unrestricted randomised use of two new generation drug-eluting coronary stents: 2-year patient-related versus stent-related outcomes from the RESOLUTE All Comers trial.
نویسندگان
چکیده
BACKGROUND In the RESOLUTE All Comers trial, the Resolute zotarolimus-eluting stent was non-inferior to the Xience V everolimus-eluting stent for the primary stent-related endpoint of target lesion failure (cardiac death, target vessel myocardial infarction, and ischaemia-driven target lesion revascularisation) at 1 year. However, data for long-term safety and efficacy from randomised studies of new generation drug-eluting coronary stents in patients treated in routine clinical practice are scarce. We report the prespecified 2-year clinical outcomes from the RESOLUTE All Comers trial. METHODS In 2008, patients with at least one coronary lesion 2.25-4.0 mm in diameter, with greater than 50% stenosis, were randomly assigned to a Resolute zotarolimus-eluting stent or a Xience V everolimus-eluting stent at 17 centres in Europe and Israel. Randomisation was by an interactive voice response system stratified by centre. Study investigators were not masked to treatment allocation; but those who did data management and analysis, and patients were masked. There were no restrictions as to the number of vessels or lesions treated, or the number of stents implanted. We assessed prespecified safety and efficacy outcomes at 2 years with specific focus on patient-related composite (all death, all myocardial infarction, all revascularisation) and stent-related composite outcomes. Analyses were by intention to treat. This study is registered with ClinicalTrials.gov, number NCT00617084. FINDINGS 1140 patients were assigned to the zotarolimus-eluting stent and 1152 to the everolimus-eluting stent; 1121 and 1128 patients, respectively, completed 2-year follow-up. The patient-related outcome (231 [20.6%] zotarolimus vs 231 [20.5%] everolimus; difference 0.1%, 95% CI-3.2 to 3.5; p=0.958) and stent-related outcome (126 [11.2%] vs 121 [10.7%]; difference 0.5%, -2.1 to 3.1; p=0.736) did not differ between groups, although rates of the stent-related outcome were substantially lower than were those for the patient-related outcome. Three patients in each group (0.3%) had very late (after 1 year) stent thrombosis. INTERPRETATION Similar safety and efficacy outcomes were sustained between two new generation drug-eluting stents at 2-year follow-up. The greater number of patient-related than stent-related events in patients with complex clinical and lesion characteristics emphasises that during long-term follow-up, the optimisation of secondary prevention is at least as important as the selection of which new generation drug-eluting stent to implant in a specific lesion. FUNDING Medtronic (USA).
منابع مشابه
Comparison of zotarolimus- and everolimus-eluting coronary stents: final 5-year report of the RESOLUTE all-comers trial.
BACKGROUND Newer-generation drug-eluting stents that release zotarolimus or everolimus have been shown to be superior to the first-generation drug-eluting stents. However, data comparing long-term safety and efficacy of zotarolimus- (ZES) and everolimus-eluting stents (EES) are limited. RESOLUTE all-comers (Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent fo...
متن کاملThe prognostic utility of the SYNTAX score on 1-year outcomes after revascularization with zotarolimus- and everolimus-eluting stents: a substudy of the RESOLUTE All Comers Trial.
OBJECTIVES This study assessed the ability of the SYNTAX score (SXscore) to stratify risk in patients treated with percutaneous coronary intervention (PCI) using zotarolimus-eluting or everolimus-eluting stents. BACKGROUND The SXscore can identify patients treated with PCI who are at highest risk of adverse events. METHODS The SXscore was calculated prospectively in 2,033 of the 2,292 patie...
متن کاملEverolimus-eluting Xience v/Promus versus zotarolimus-eluting resolute stents in patients with diabetes mellitus.
OBJECTIVES This study sought to compare everolimus-eluting stents (EES) versus Resolute zotarolimus-eluting stents (ZES) in terms of patient- or stent-related clinical outcomes in an "all-comer" group of patients with diabetes mellitus (DM) who underwent percutaneous coronary intervention. BACKGROUND DM significantly increases the risk of adverse events after percutaneous coronary interventio...
متن کاملAngiographic and clinical comparison of novel Orsiro Hybrid sirolimus-eluting stents and Resolute Integrity zotarolimus-eluting stents in all-comers with coronary artery disease (ORIENT trial): study protocol for a randomized controlled trial
BACKGROUND The Orsiro Hybrid sirolimus-eluting stent is a newly developed third-generation drug-eluting stent, featuring a unique dual-polymer mix. An active bioabsorbable polymer delivers the anti-proliferative drug, sirolimus, via controlled release, while a passive biocompatible polymeric coating shields the metallic strut from surrounding tissue, preventing interaction. To date, the Orsiro ...
متن کاملClinical outcome following stringent discontinuation of dual antiplatelet therapy after 12 months in real-world patients treated with second-generation zotarolimus-eluting resolute and everolimus-eluting Xience V stents: 2-year follow-up of the randomized TWENTE trial.
OBJECTIVES The aim of this study was to assess the safety and efficacy of the implantation of Resolute zotarolimus-eluting stents (ZES) (Medtronic Inc., Santa Rosa, California) and Xience V everolimus-eluting stents (EES) (Abbott Vascular, Santa Clara, California) following strict discontinuation of dual antiplatelet therapy (DAPT) after 12 months. BACKGROUND Only limited long-term follow-up ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Lancet
دوره 377 9773 شماره
صفحات -
تاریخ انتشار 2011