Testing of the Prototype Receiver for ITER ECE Diagnostic

نویسندگان

  • S. Danani
  • M. E. Austin
  • M. W. Brookman
  • H. K. B. Pandya
  • Vinay Kumar
چکیده

The Electron Cyclotron Emission (ECE) diagnostic system in ITER provides essential information for plasma control and for evaluating the plasma performance. It measures the electron temperature profile (edge/core), electron temperature fluctuations and radiated power in the electron cyclotron frequency range from the plasma. Virginia Diodes Inc. (VDI) has designed and developed a stateof-the-art prototype receiver to detect emission in the 200-300 GHz frequency range. The prototype receiver developed by VDI has been tested at DIII-D tokamak to check its performance by measuring higher frequency ECE harmonics in high temperature plasmas. Bench testing verifies the receiver’s band coverage and noise temperatures. Good sensitivity has been obtained meeting the ITER requirement. Also, the receiver performance is assessed for ITER by comparing the data from the receiver and the existing Michelson interferometer for the same DIII-D plasma shot. The measurement results show that the receiver provides accurate temperature information for the plasma emission throughout the frequency band.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Update on the status of the ITER ECE diagnostic design

Considerable progress has been made on the design of the ITER electron cyclotron emission (ECE) diagnostic over the past two years. Radial and oblique views are still included in the design in order to measure distortions in the electron momentum distribution, but the oblique view has been redirected to reduce stray millimeter radiation from the electron cyclotron heating system. A major challe...

متن کامل

Receiver Operating Characteristic (ROC) Curve Analysis for Medical Diagnostic Test Evaluation

This review provides the basic principle and rational for ROC analysis of rating and continuous diagnostic test results versus a gold standard. Derived indexes of accuracy, in particular area under the curve (AUC) has a meaningful interpretation for disease classification from healthy subjects. The methods of estimate of AUC and its testing in single diagnostic test and also comparative studies...

متن کامل

The ITER bolometer diagnostic: status and plans.

A consortium consisting of four EURATOM Associations has been set up to develop the project plan for the full development of the ITER bolometer diagnostic and to continue urgent R&D activities. An overview of the current status is given, including detector development, line-of-sight optimization, performance analysis as well as the design of the diagnostic components and their integration in IT...

متن کامل

Physics and Engineering Design of the ITER Electron Cyclotron

Submitted for the DPP15 Meeting of The American Physical Society Physics and Engineering Design of the ITER Electron Cyclotron Emission Diagnostic1 W.L. ROWAN, M.E. AUSTIN, S. HOUSHMANDYAR, P.E. PHILLIPS, IFS, The University of Texas at Austin, J.H. BENO, A. OUROUA, D.A. WEEKS, CEM, The University of Texas at Austin, A.E. HUBBARD, J.A. STILLERMAN, MIT-PSFC, R.E. FEDER, A. KHODAK, G. TAYLOR, PPP...

متن کامل

Summary of ECE Presentations at EC-19

At the EC-19 workshop there were ten presentations in the topic of diagnosing and heating plasmas with Electron Cyclotron Emission (ECE) and Electron Bernstein Wave (EBW). Innovations continue in designs of ECE systems while tried-and-true instruments still provide adequate data to explore new areas of research. Heterodyne radiometers and Michelson interferometers carry on as the bedrock of ECE...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017