Optimisation of a reagentless laccase electrode for the detection of the inhibitor azide.
نویسندگان
چکیده
Here we report on the optimisation of a reagentless enzyme sensor for the detection of azide based on the mediated reduction of O2 by a laccase enzyme co-immobilised in a redox hydrogel on electrode surfaces. The sensor response is shown to be influenced by the enzyme loading, the electrolyte pH and ionic strength. The response of the sensor is stable, decreasing by only 25% over a sixteen-hour period. Reproducible inhibition curves for the determination of azide levels from cyclic voltammetric scans can be obtained by normalisation of the sensor response. The resulting enzyme inhibition biosensor can detect levels of azide as low as 2.5 microM under these conditions. Constant potential amperometric detection at the laccase enzyme electrode in a flow injection set-up yields a peak current for inhibition of the mediated reduction of O2. Reproducible peak currents and areas (8.0 and 6.3% RSD, respectively, for n = 11) are obtained for repeated injections of 100 microM azide. Reproducible response curves can be obtained by injection of a 25 mM azide sample and assuming that the peak height and peak area obtained represent 100% inhibition of the enzyme.
منابع مشابه
Direct electron transfer catalysed by enzymes: application for biosensor development.
The ability to catalyse an electrode reaction via direct (mediatorless) electron transfer has been demonstrated for a number of redox enzymes. In the case of mediatorless electron transfer, the electron is transferred directly from the electrode to the substrate molecule via the active site of the enzyme, or vice versa. The electron itself is the second substrate for the reaction. An important ...
متن کاملتهیه الکترود یونگزین بر پایه پلی وینیل کلرید برای اندازهگیری دیمتیل آمینو اتیلکلراید هیدروکلراید
Dimethyl amino ethyl chloride hydrochloride (DMC) is a primary material of fuel of dimethyl amino ethyl azide (DMAZ) that is a good alternative for hydrazine derivatives in the aerospace industry. Some amount of unreacted DMC remains in the wastewater in production processes of DMAZ (95% wt.) that due to toxicity and corrosion effect of DMC, determination of this compound in DMAZ waste is ine...
متن کاملDetection of Ascorbic Acid in Biological Samples by a New Modified Glassy Carbon Electrode
The present work describes the construction of a new modified electrode by casting the appropriate mixture of a metallocene, which has been introduced in the experimental part, as a mediator at the surface of glassy carbon (GC) electrode. The proposed modified GC electrode was used for the determination of ascorbic acid (AA) in phosphate buffer (PB) solution (pH = 4.0). When compared to bare GC...
متن کاملVoltammetric Detection of Dopamine and Ascorbic Acid Using a Multi-Walled Carbon Nanotubes/Schiff Base Complex of Cobalt-Modified Glassy Carbon Electrode
The surface of the glassy carbon electrode (GCE) is modified with the composite of new Cobalt complex with a tetradentate Schiff base ligand derived from 3-ethoxysalicylaldehyde and 4,5-dimethyl orthophenylenediamine (CoOEtSal) and multi-walled carbon nanotube (MWCNT). The electrochemical oxidation of ascorbic acid (AA) and dopamine (DA) at the modified electrode was studied using the cyclic an...
متن کاملSynergetic signal amplification of multi-walled carbon nanotubes-Cetyltrimethylammonium Bromide and Poly-L-Arginine as a highly sensitive detection platform for Rutin
In this research, a glassy carbon electrode was coated with a thin layer of multi-walled carbon nanotubes in the presence of the surfactant and subsequently was electro-polymerized with Poly-L-arginine (P-L-Arg). The prepared electrode was used as an effective sensor for the quantitative detection of Rutin (Ru). The fabricated electrode exhibited good electrochemical performance with low electr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Analyst
دوره 123 10 شماره
صفحات -
تاریخ انتشار 1998