On the specificity of cyclodextrin complexes detected by electrospray mass spectrometry.
نویسندگان
چکیده
Alpha-cyclodextrin complexes with linear alpha,omega-dicarboxylic acids were investigated by electrospray mass spectrometry. These hydrophobic complexes are known to have an equilibrium binding constant that increases with the diacid chain length. However, the electrospray mass spectrometry (ES-MS) spectra showed that the relative intensity of the complex did not vary significantly with chain length. This contradiction is caused by a contribution of nonspecific adducts to the signal of the complex in ES-MS. In order to estimate the contribution of nonspecific adducts to the total intensity of the complexes with alpha-cyclodextrin, the comparison was made between alpha-cyclodextrin and maltohexaose, the latter being incapable of making inclusion complexes in solution. The signal observed for complexes between diacids and maltohexaose can only result from nonspecific electrostatic aggregation, and is found to be more favorable with the shorter diacids. This is also supported by MS/MS experiments. A procedure is described which allows estimation of the contribution of the nonspecific complex in the spectra of the complexes with alpha-cyclodextrin by using the relative intensity of the complex with maltohexaose. The contribution of the specific complex to the total signal intensity is found to increase with the diacid chain length, which is in agreement with solution behavior.
منابع مشابه
Influence of response factors on determining equilibrium association constants of non-covalent complexes by electrospray ionization mass spectrometry.
A method for determining the equilibrium association constant of a complexation reaction A + B left harpoon over right harpoon AB by electrospray ionization mass spectrometry is described. The method consists in measuring the relative intensities of the peaks corresponding to A and to AB in equimolar A-B solutions at different concentrations C(0). The results are fitted by a non-linear least-sq...
متن کاملAmino Acid Profiling by Reactive Desorption Electrospray Ionization Tandem Mass Spectrometry (DESI-MS/MS)
Desorption electrospray ionization mass spectrometry (DESI MS) has gained significant recognition over the past few years because of its simplicity and rapid throughput capabilities, allowing for the direct analysis of samples with a wide variety of sizes, shapes, and chemistries. Addition of various reagents into the DESI spray solvent enables atmospheric pressure ion molecule reactions betwee...
متن کاملInclusion complexes of ionic liquids and cyclodextrins: are they formed in the gas phase?
The interaction of imidazolium-based ionic liquids with α- and β-cyclodextrins was investigated by electrospray ionization mass spectrometry with variable collision induced dissociation energy and quantum chemical gas-phase calculations. The center-of-mass energy at which 50% of a precursor ion decomposes (Ecm,1/2) was determined for the isolated [cyclodextrin + cation](+) or [cyclodextrin + an...
متن کاملStudying noncovalent protein complexes by electrospray ionization mass spectrometry.
Electrospray ionization mass spectrometry has been used to study protein interactions driven by noncovalent forces. The gentleness of the electrospray ionization process allows intact protein complexes to be directly detected by mass spectrometry. Evidence from the growing body of literature suggests that the ESI-MS observations for these weakly bound systems reflect, to some extent, the nature...
متن کاملQuantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)
The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Society for Mass Spectrometry
دوره 13 8 شماره
صفحات -
تاریخ انتشار 2002