Calculating organ doses of patients in spiral CT using EGS 4 Monte - Carlo simulation of voxel phantom
نویسندگان
چکیده
According as the progress of medical technique, X-ray imaging systems have been progressed. Especially, X-ray CT imaging system have been improved and widely used as general diagnostic methods nowadays in Japan. However, the doses for patients of X-ray CT imaging are relatively higher than of other Xray examinations. The dose estimations and optimizations on X-ray CT are very important for medical radiation protection, so that we estimated organ doses on spiral X-ray CT imaging by the method of Monte-Carlo simulations. A voxel phantom of a Japanese male developed in JAERI was used for the simulations. As MonteCarlo simulation code, EGS4 was selected. The organ doses for X-ray CT imaging of lungs and liver has been calculated with the same conditions as the actual X-ray CT diagnoses in a hospital. For conventional CT imaging, the doses for each slice have also been estimated. They could be helpful for risk estimations of X-ray CT examinations.
منابع مشابه
Thorax organ dose estimation in computed tomography based on patient CT data using Monte Carlo simulation
Background: This study presents patient specific and organ dose estimation in computed tomography (CT) imaging of thorax directly from patient CT image using Monte Carlo simulation. Patient's CT image is considered as the patient specific phantom and the best representative of patient physical index in order to calculate specific organ dose. Materials and Methods: EGSnrc /BEAMnr...
متن کاملEstimation of Photon Specific Absorbed Fractions in Digimouse Voxel Phantom using Monte Carlo Simulation Code FLUKA
Background: Most preclinical studies are carried out on mice. For internal dose assessment of a mouse, specific absorbed fraction (SAF) values play an important role. In most studies, SAF values are estimated using older standard human organ compositions and values for limited source target pairs.Objective: SAF values for monoenergetic photons of energies 15, 50, 100, 500, 1000 and 4000 keV...
متن کاملEvaluation of Electron Specific Absorbed Fractions in Organs of Digimouse Voxel Phantom Using Monte Carlo Simulation Code FLUKA
Background: For preclinical evaluations of radiopharmaceuticals, most studies are carried out on mice. Values of electron specific absorbed fractions (SAF) have had vital role in the assessment of absorbed dose. In past studies, electron specific absorbed fractions were given for limited source target pairs using older reports of human organ compositions.Objective: Electron specific absorbed fr...
متن کاملEvaluation of the RtDosePlan Treatment Planning System using Radiochromic Film and Monte Carlo Simulation
Introduction: GafChromic EBT films are one of the self-developing and modern films commercially available for dosimetric verification of treatment planning systems (TPSs). Their high spatial resolution, low energy dependence and near-tissue equivalence make them suitable for verification of dose distributions in radiation therapy. This study was designed to evaluate the dosimetric parameters of...
متن کاملOrgan and effective dose arising from conventional diagnostic X-ray examinations by Monte Carlo simulation (MCNP-4C Code)
ABSTRACTBackground: Monte Carlo simulation has been used by many researchers to calculate organ and effective dose of patients arising from conventional X-ray examinations. In this study the radiation transport code, MCNP-4C, has been used to perform Monte Carlo simulations to estimate radiation dose delivered to different organs in conventional X-ray examinations.Material and Methods: In this...
متن کامل