Rapid assessment of left ventricular segmental wall motion, ejection fraction, and volumes with single breath-hold, multi-slice TrueFISP MR imaging.

نویسندگان

  • David S Fieno
  • Louise E J Thomson
  • Piotr J Slomka
  • Aiden Abidov
  • Hidetaka Nishina
  • Daisy Chien
  • Sean W Hayes
  • Rola Saouaf
  • Guido Germano
  • John D Friedman
  • Daniel S Berman
چکیده

BACKGROUND AND OBJECTIVE To reduce imaging time and complexity, we sought to determine whether single breath-hold, multi-slice TrueFISP (SB-MST) magnetic resonance imaging (MRI) method is comparable to standard multi-breath-hold, multi-slice TrueFISP (MB-MST) for assessment of left ventricular (LV) wall motion abnormality (WMA), volumes, and ejection fraction (EF). METHODS AND RESULTS We studied 62 patients having cardiac MRI at 1.5-Tesla. After acquiring standard MB-MST (one slice per breath-hold), SB-MST was performed, acquiring 3 short- and 2 long-axis views over only 20 heartbeats. Using both techniques, wall motion was scored using a 6-point, 17-segment LV model for all scans (62 patients x 2 techniques/patient = 124 scans) on two separate occasions. Separately, EF and ventricular volumes were evaluated using both MB-MST and SB-MST. For all analyses, MB-MST was considered the standard against which SB-MST was compared. Twenty-six of 62 patients exhibited at least one segmental WMA by MB-MST. Exact agreement for wall motion was found in 965/1054 segments (92%, kappa = 0.74, p < 0.001), and agreement was within 1 score point in 1010/1054 segments (96%). Considering a score >1 abnormal, exact agreement for presence of WMA was found in 131/193 segments (68%) abnormal by MB-MST and for absence of WMA in 838/861 segments (97%) normal by MB-MST. Agreement within 1 score point occurred in 167/193 abnormal (87%) and in 843/861 normal segments (98%). There were no significant differences in agreement between first and second read of the data. Variability of SB-MST on read one versus read two was small (5%, 996/1054 segments read identically, p = ns) and statistically identical to variability of MB-MST on read one versus read two (4%, 1007/1054 segments read identically, p = ns). For end-diastolic volumes, end-systolic volumes, and EF using SB-MST compared to MB-MST, mean differences were 9 +/- 15 ml, 6 +/- 12 ml, and 2 +/- 5%, and correlations were r = 0.97, 0.98 and 0.95, respectively. CONCLUSION SB-MST accurately assesses wall motion, volumes and EF. This approach may serve as a screening exam for assessment of WMA and, under select circumstances, may substitute for standard multi-breath-hold method in situations requiring rapid accurate assessments of LV function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

STRUCTURE AND FUNCTION Rapid Evaluation of Right and Left Ventricular Function and Mass Using Real-Time True-FISP Cine MR Imaging Without Breath-Hold: Comparison with Segmented True-FISP Cine MR Imaging with Breath-Hold

Purpose. To evaluate the accuracy of cardiac function measured with real-time true fast imaging with steady-state precession (True-FISP) cine without breath-hold compared with those measured from segmented True-FISP cine with breath-hold. Methods. Eighteen consecutive patients and six healthy volunteers were enrolled in the study group. Both realtime multislice True-FISP cine imaging without br...

متن کامل

Single and biplane TrueFISP cardiovascular magnetic resonance for rapid evaluation of left ventricular volumes and ejection fraction.

INTRODUCTION Cardiovascular magnetic resonance (CMR) allows very accurate, but time-consuming, volume assessment by the short-axis slice summation technique. The single and biplane methods of volume assessment are used less, partly because FLASH cine imaging provides poor blood-myocardium contrast in long-axis views. TrueFISP gives excellent blood-myocardium contrast, even in patients with hear...

متن کامل

Assessment of global and regional left ventricular function and volumes with 64-slice multi-slice computed tomography: a comparison with 2D echocardiography

Introduction: In patients with coronary artery disease (CAD), LV function and volumes are important parameters for long-term prognosis. 64-slice MSCT allows non-invasive assessment of the coronary arteries, but the accuracy of 64-slice MSCT for assessment of LV volumes and function is unknown. Methods: A head-to-head comparison between 64-slice MSCT and 2D echocardiography was performed in 40 p...

متن کامل

Single breath-hold real-time MR cardiac cine for evaluation of left ventricular function

Background Magnetic Resonance (MR) cardiac cine is generally accepted as the gold standard for left ventricular (LV) volume assessment. Recently, Real-Time (RT) cine with sparse sampling technique and iterative reconstruction has been applied to accelerate cine MR. However, in prospective electrocardiogram (ECG) triggered RT cine MR, it may be difficult to capture the true end diastole phase be...

متن کامل

Effect of oral propranolol on rest and exercise left ventricular ejection fraction, volumes, and segmental wall motion in patients with angina pectoris. Assessment with equilibrium gated blood pool imaging.

The effect of oral propranolol on left ventricular ejection fraction, left ventricular volumes, cardiac output, and segmental wall motion was assessed with multigated blood pool imaging both at rest and during supine exercise in 15 patients with angina pectoris. Propranolol had no effect on resting left ventricular ejection fractions. Before propranolol, they did not change during exercise, whe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance

دوره 8 3  شماره 

صفحات  -

تاریخ انتشار 2006