Tribological performance of the biological components of synovial fluid in artificial joint implants
نویسندگان
چکیده
The concentration of biological components of synovial fluid (such as albumin, globulin, hyaluronic acid, and lubricin) varies between healthy persons and osteoarthritis (OA) patients. The aim of the present study is to compare the effects of such variation on tribological performance in a simulated hip joint model. The study was carried out experimentally by utilizing a pin-on-disk simulator on ceramic-on-ceramic (CoC) and ceramic-on-polyethylene (CoP) hip joint implants. The experimental results show that both friction and wear of artificial joints fluctuate with the concentration level of biological components. Moreover, the performance also varies between material combinations. Wear debris sizes and shapes produced by ceramic and polyethylene were diverse. We conclude that the biological components of synovial fluid and their concentrations should be considered in order to select an artificial hip joint to best suit that patient.
منابع مشابه
14-3-3 Protein is Detectable in Blood Serum and Fetlock Joint Synovial Fluid of High Performance Horses
Objective: To investigate whether 14-3-3 eta protein is detectable in synovial fluid and blood serum of high performance horses and to study whether any significant correlation between this and matrix metalloproteinase 1 and 3 in horse synovial fluid. Design: Clinical study. Animals: Eleven standard breed horses (seven high performances and four controls). Procedures: Blood serum and fetlock...
متن کاملTribological investigation of diamond-like carbon coated micro-dimpled surface under bovine serum and osteoarthritis oriented synovial fluid
Osteoarthritis-oriented synovial fluid (OASF), i.e., that typical of a patient with osteoarthritis, has different physical and biological characteristics than bovine serum (BS), a lubricant widely used in biotribological investigations. Micro-dimpled and diamond-like carbon- (DLC) coated surfaces are key emerging interfaces for orthopedic implants. In this study, tribological performances of di...
متن کاملOn the matter of synovial fluid lubrication: implications for Metal-on-Metal hip tribology.
Artificial articular joints present an interesting, and difficult, tribological problem. These bearing contacts undergo complex transient loading and multi axes kinematic cycles, over extremely long periods of time (>10 years). Despite extensive research, wear of the bearing surfaces, particularly metal-metal hips, remains a major problem. Comparatively little is known about the prevailing lubr...
متن کاملSynovial fluid inflammatory cytokines and proteins in clinically healthy and arthritic joint of dromedary camels (Camelus dromedarius)
Analyzing the synovial fluid is one of the common methods to diagnose the articular problems to detect the stage and express the prognosis. Such gross, cytological, and biochemical analysis of synovial fluids can aid in the diagnosis of various joint diseases. Objectives: Normal values for synovial fluid in the camels have been described previously; however, there are no reports regarding conce...
متن کاملComparative study of synovial fluid and serum protein electrophoretic pattern of river buffalo (Bubalus bubalis) in Ahvaz
Electrophoresis is a meticulous method in para-clinical science but has received less attention. In this study, the protein profile of synovial fluid of carpal joint and blood serum in buffalo was detected. Sampling was performed by arthrocentesis of 80 left and right forelimbs and obtaining blood serums of 40 Bubalus bubalis in Ahvaz industrial slaughterhouse. Samples were str...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2015