Clinical evaluation of the Terumo Capiox FX05 hollow fiber oxygenator with integrated arterial line filter.

نویسندگان

  • Joseph Deptula
  • Melinda Valleley
  • Kimberly Glogowski
  • John Detwiler
  • James Hammel
  • Kim Duncan
چکیده

Perfusion techniques and equipment in pediatric open heart surgery have continued to focus on decreasing prime volumes and lowering surface areas of the cardiopulmonary bypass circuit. While this has improved drastically over the last 20 years, greater demand is being placed on the perfusionist to reduce the deleterious effects of bypass without compromising safety or efficiency. Specifically, manufacturers of disposable perfusion equipment have focused on providing pediatric perfusionists with oxygenators that provide the smallest prime and surface area possible while attempting to maximize performance. Recently,Terumo Cardiovascular has introduced the Capiox FX05, a neonatal hollow fiber oxygenator that includes an integrated arterial line filter. The FX05 provides a blood flow range of 0.1-1.5 L/min and a low priming volume of 43 mL. Additionally, it is coated with X Coating, a biocompatible, hydrophilic polymer surface coating that reduces platelet adhesion and protein denaturation. The purpose of this study was to test the FX05 for gas transfer, blood path resistance, and blood handling characteristics in a standardized clinical setting. Heat exchange coefficients were also calculated during the cooling and warming period. Other data analyzed includes bypass circuit prime volumes and initial patient hematocrit along with the total operative homologous blood donor exposures. In summary, the FX05 offers good gas exchange capabilities and a low pressure drop during normal cardiopulmonary bypass parameters along with the safety of an integrated arterial line filter. Furthermore, the FX05 with integrated filter allows a reduction in overall bypass prime volume and surface area while promoting the reduction of homologous blood transfusions, optimizing hemostasis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A clinical evaluation of the Terumo Capiox SX18R hollow fiber oxygenator.

The Terumo Capiox SX18R is a commercially available, low prime, reverse phase, hollow fiber membrane oxygenator. The oxygenator consists of a 1.8 m2 microporous polypropylene hollow fiber bundle, a 2200 cm2 tubular stainless steel heat exchanger, and an open hard shell venous reservoir with integral cardiotomy filter. The Terumo Capiox SX18R oxygenator was evaluated to determine its clinical ox...

متن کامل

Randomized trial of the Terumo Capiox FX05 oxygenator with integral arterial filter versus Terumo Capiox Baby RX05 and Terumo Capiox AF02 arterial filter in infants undergoing cardiopulmonary bypass.

UNLABELLED The purpose of this clinical trial was to evaluate the effect of the Terumo Capiox FX05 oxygenator with integrated arterial filter during cardiopulmonary bypass (CPB) compared with the Terumo Capiox RX05 Baby RX and arterial filter on inflammatory mediators and blood product utilization. Forty patients weighing less than 10 kg who underwent congenital heart surgery utilizing cardiopu...

متن کامل

Clinical gaseous microemboli assessment of an oxygenator with integral arterial filter in the pediatric population.

The use of an arterial line filter (ALF) within the pediatric cardiopulmonary bypass (CPB) circuit is not a new concept. It has always presented the perfusionist with a circuit component that while valuable, increased prime volume. The purpose of this study was to evaluate the change in prime volume and emboli between a conventional oxygenator with separate ALF and a new generation oxygenator w...

متن کامل

In vitro evaluation of gaseous microemboli handling of cardiopulmonary bypass circuits with and without integrated arterial line filters.

The delivery of gaseous microemboli (GME) by the cardiopulmonary bypass circuit should be minimized whenever possible. Innovations in components, such as the integration of arterial line filter (ALF) and ALFs with reduced priming volumes, have provided clinicians with circuit design options. However, before adopting these components clinically, their GME handling ability should be assessed. Thi...

متن کامل

Can the oxygenator screen filter reduce gaseous microemboli?

Gaseous microemboli (GME) define small bubbles as < 200 microm in size. GME are reported to increase morbidity after cardiopulmonary bypass (CPB) and cardiac surgery. To prevent intrusion of GME into the systemic circulation during CPB, arterial line filtration is generally recommended. New trends in oxygenator design promote location of arterial filtration as an integral part of the oxygenator...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 41 4  شماره 

صفحات  -

تاریخ انتشار 2009