Passive and active ventricular elastances of the left ventricle
نویسندگان
چکیده
BACKGROUND Description of the heart as a pump has been dominated by models based on elastance and compliance. Here, we are presenting a somewhat new concept of time-varying passive and active elastance. The mathematical basis of time-varying elastance of the ventricle is presented. We have defined elastance in terms of the relationship between ventricular pressure and volume, as: dP = EdV + VdE, where E includes passive (Ep) and active (Ea) elastance. By incorporating this concept in left ventricular (LV) models to simulate filling and systolic phases, we have obtained the time-varying expression for Ea and the LV-volume dependent expression for Ep. METHODS AND RESULTS Using the patient's catheterization-ventriculogram data, the values of passive and active elastance are computed. Ea is expressed as [formula: see text] Epis represented as: [formula: see text]. Ea is deemed to represent a measure of LV contractility. Hence, Peak dP/dt and ejection fraction (EF) are computed from the monitored data and used as the traditional measures of LV contractility. When our computed peak active elastance (Ea,max) is compared against these traditional indices by linear regression, a high degree of correlation is obtained. As regards Ep, it constitutes a volume-dependent stiffness property of the LV, and is deemed to represent resistance-to-filling. CONCLUSIONS Passive and active ventricular elastance formulae can be evaluated from a single-beat P-V data by means of a simple-to-apply LV model. The active elastance (Ea) can be used to characterize the ventricle's contractile state, while passive elastance (Ep) can represent a measure of resistance-to-filling.
منابع مشابه
The effect of high-intensity interval training (HIIT) and quercetin supplementation on dimension and functional left ventricular adaptations in men with hypertension and CAD after PCI
Objective: The present study investigated the effects of 10-week High Intensity Interval Training (HIIT) and quercetin consumption on dimension and functional left ventricular adaptations in men with hypertension and coronary artery disease (CAD) after percutaneous coronary intervention (PCI). Materials and Methods: In this semi-experimental randomized, placebo‑controlled and double‑blind s...
متن کاملPressure-diameter relations during early diastole in dogs. Incompatibility with the concept of passive left ventricular filling.
We studied left ventricular (LV) pressure-diameter relations in 13 open-chest mongrel dogs to explore whether ventricular filling is passive, active, or a combination of both. Left ventricular internal diameter along the minor axis and thickness of the LV free wall were measured with ultrasonic dimension gauges. Pressures in the LV, left atrium (LA), and aorta were measured with catheter-tip mi...
متن کاملCorrelation between the Level of Creatinine, Serum Cardiac Troponines and Left Ventricle Function Tests in Patients with Chronic Renal Diseases without Acute Coronary Syndrome
Background and Objectives: The aim of this study was to survey the relationship between the level of creatinine,cardiac troponins serum and the function of the left ventricle in patients with kidney insufficiency,without acute coronary syndrome. Materialsand Methods:The sample was150 patients with nondialysis chronic kidney disease without acute coronary syndrome, hospitalized at I...
متن کاملبررسی یافته های اکوکاردیو گرافیک قلبی در بیماران سیروز کبدی
Introduction: Cardiovascular abnormalities have been reported in liver cirrhosis (LC). In these patients, cardiac symptoms and physical signs occur as the liver functions worsen. Cirrhosis is associated with hyper dynamic circulation and beta-adrenergic system changes responsible for the cardiovascular abnormalities. The purpose of the present study was to explore the echocardiographic findi...
متن کاملA New Minimum Order Lumped-Parameter Model of Circulatory System for Patients with Suffered Left and Right-Sided Heart Failure
In this study a new minimum lumped electrical model of total circulatory system through numerical solutions to approximate the response of the human circulatory system was presented. Among five existent ventricular elastances as activity function of heart pumps, a more accurate model was chosen as well as the operation of baroreflex system to accommodate variations in heart rate and systemic va...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BioMedical Engineering OnLine
دوره 4 شماره
صفحات -
تاریخ انتشار 2005