A cataluminescence gas sensor based on nanosized V2O5 for tert-butyl mercaptan.

نویسندگان

  • Huili Zhang
  • Lichun Zhang
  • Jing Hu
  • Pingyang Cai
  • Yi Lv
چکیده

This work proposed a gas sensor for the determination of tert-butyl mercaptan, one of the highly toxic volatile sulfur compounds, which was based on cataluminescence emission during its catalytic oxidation on the surface of nanosized V(2)O(5). The cataluminescence characteristics and the optimum conditions, including the morphology of sensing material, the wavelength of cataluminescence emission, the oxygen flow rate and working temperature were investigated in detail. Under the optimized conditions, the calibration curve of the relative cataluminescence intensity versus the concentration of tert-butyl mercaptan vapor was made, with the linear range of 5.6-196 microg mL(-1) and the detection limit of 0.5 microg mL(-1) (S/N=3). The relative standard deviation (R.S.D.) (n=5) of relative cataluminescence intensity for 84 microg mL(-1) tert-butyl mercaptan was 3.6%. There is no or weak response to some common substances, such as formic acid, alcohol (methanol, ethanol, propanol, isopropanol, n-butanol, isoamyl alcohol), o-dichlorobenzene, acetonitrile, ethyl acetate, aldehyde (formaldehyde, acetaldehyde and propanal), 1,2-dichloroethane and ammonia. Furthermore, the proposed sensor was successfully used for determining tert-butyl mercaptan in four artificial samples, with a good recovery. The results demonstrated that the proposed gas sensor had a promising capability for the tert-butyl mercaptan in routine monitoring.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Oxidative Stress of Mercaptan Odorant Due to Occupational Exposure: Adverse Effects on the Cholinergic System

Background: Tert-butyl mercaptan is one of the frequently used odorants derived from natural gases. It has been declared as a health hazard by the Occupational Safety and Health Administration (OSHA) in the USA. There is not much information available about the mercaptans long-term toxicity secondary to occupational exposure. This study was conducted to evaluate the oxidative stress caused by m...

متن کامل

Fast and environmental-friendly degradation of tert-butyl mercaptan from contaminated soil using bimetallic-modified Fenton process

In this work, the fast remediation of tert-butyl mercaptan from the polluted soil via a bimetallic Fenton treatment that included Fe2+/Fe3+/Fe0/Cu2+ in the presence of gasoline was studied. The analysis of variance and the Pareto analysis resulting from the central composite design (CCD) showed that the H2O2, CuSO4<...

متن کامل

Efficient Rapid Deodorization of Mercaptan-Contaminated Soil by Sono-Fenton Process: Response Surface Modeling and Optimization

The entry of mercaptans into the environment as an odor pollutant has always been considered as one of the environmental concerns. In this research, a sonochemical oxidation (sono-Fenton) method was used for rapid deodorizing of tert-butyl mercaptan (TBM) contaminated soil. The design of the experiments was conducted by CCD method and the effect of four different factors was investigated on the...

متن کامل

An energy-transfer cataluminescence reaction on nanosized catalysts and its application to chemical sensors

When reductive gases pass over the surface of nanosized catalysts, a kind of chemiluminescence named cataluminescence (CTL) can be generated due to the production of excited intermediates. Here we report the observation of an energy transfer process between excited intermediates and the nanosized catalysts. The CTL is quenched when introducing Ho3+, Co2+ and Cu2+ into the catalyst, while new in...

متن کامل

Studies of the Cataluminescence of Benzene Homologues on Nanosized γ–Al2O3/Eu2O3 and the Development of a Gas Sensor for Benzene Homologue Vapors

The cataluminescence (CTL) of benzene and the benzene homologues toluene and xylene on nanosized γ–Al2O3 doped with Eu2O3 (γ–Al2O3/Eu2O3) was studied and a sensor of determining these gases was designed. The proposed sensor showed high sensitivity and selectivity at an optimal temperature of 432 oC, a wavelength of 425 nm and a flow rate of 400 mL/min. Quantitative analysis was performed at the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 82 2  شماره 

صفحات  -

تاریخ انتشار 2010