Testing Varistors against the VDE 0160 Standard

نویسنده

  • François Martzloff
چکیده

High-energy surge tests have been pe$ormed on metal-oxide varistors of a type in common use, according to a proposed ZEC standard derived from German Standard W E 01 60. l%e surge generator used for the test was a prototype commercial device developed especially to deliver the 1000300 ps waveform speczjied by W E Standard 0160. Depending on the position of the varistor within its manufacturing tolerance band, failure or degradation can occur, validating the concern that this test requirement may be too severe for universal application.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Incompatibility Between the 100/1300 Surge Test and Varistor Failure Rates

Significance: Part 2 – Development of standards – Reality checks Demonstration ad absurdum: Accepting the premise of prevalent 100/1300 high-energy surges and modeling the response of typical metal-oxide varistors leads to the conclusion that most of the billions of varistors in service should fail at alarming rates – but we know they do not. Ergo, the premise is not valid. This paper was part ...

متن کامل

Nondestructive Testing in Diagnostics of High-voltage Varistors

− High voltage varistors that consist of grained ZnO have to be tested before assembling. The recommended method for standard industrial testing of varistors demands application of high voltages and intensive currents that is inconvenient and needs extensive power consumption. Nondestructive methods for varistor quality and endurance evaluation have been proposed. They rely on the application o...

متن کامل

Internal Protection of Transformer Windings Against Transeint Surges Using ZnO Varistors

Power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. Once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. The resonant overvoltages may destroy the insulation between turns and cause to insul...

متن کامل

Internal Protection of Transformer Windings Against Transeint Surges Using ZnO Varistors

Power system overvoltages due to switching, lightning and other disturbances are the main problem for designers of the power transformers. Once some frequencies of the incoming surges match with some of the natural frequencies of transformer winding, the resonance phenomenon is expected in transformer winding. The resonant overvoltages may destroy the insulation between turns and cause to insul...

متن کامل

Quality Assessment of Metal Oxide Varistors by Noise Spectroscopy

− The noise spectroscopy in a frequency domain has been used as a diagnostic tool of high-voltage varistors consisting of grained ZnO. The electrical properties of tested specimens have been described. In this experimental study, we present the applied measurement system and the results of noise spectrum measurements for the selected structures of 280 V varistors. Noise properties are related t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002