High-resolution nitrogen gas profiles in sediment porewaters using a new membrane probe for membrane-inlet mass spectrometry

نویسندگان

  • Hilairy E. Hartnett
  • Sybil P. Seitzinger
چکیده

A probe inlet for membrane-inlet mass spectrometry (MIMS) was developed to measure dissolved nitrogen and argon gas in sediment porewaters. This technique represents a significant improvement in the measurement of dissolved gas ratios in sediment cores and in small volume samples ( < 5 ml). The probe is stable, inexpensive and has relatively fast equilibration times (f 4–5 min) for dissolved N2/Ar ratio analyses. The membrane probe is mounted at the end of a stainless steel capillary (0.75 mm OD) connected directly to the inlet system of a quadrupole mass spectrometer. Themembrane isf 1mm 0.5mm resulting in profiles that have a depth resolution of < 2mm. Nitrogen/argon ratios measured with the probe inlet have a precision of < 0.2%. Porewater N2/Ar ratios measured in cores collected from Raritan Bay, NJ, indicated that N2 was in equilibrium with the atmosphere in overlying waters and that nitrogen was up to 8% supersaturated by a depth of 1 cm. The increase in N2 is consistent with nitrogen production from denitrification of f 2 mmol N2 m 2 day . High-resolution nitrate profiles also provide evidence for denitrification, with nitrate being depleted at the same depth horizon where N2 gas concentrations are increasing. D 2003 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous measurement of denitrification and nitrogen fixation using isotope pairing with membrane inlet mass spectrometry analysis.

A method for estimating denitrification and nitrogen fixation simultaneously in coastal sediments was developed. An isotope-pairing technique was applied to dissolved gas measurements with a membrane inlet mass spectrometer (MIMS). The relative fluxes of three N(2) gas species ((28)N(2), (29)N(2), and (30)N(2)) were monitored during incubation experiments after the addition of (15)NO(3)(-). For...

متن کامل

Calibration of an in situ membrane inlet mass spectrometer for measurements of dissolved gases and volatile organics in seawater.

Use of membrane inlet mass spectrometers (MIMS) for quantitative measurements of dissolved gases and volatile organics over a wide range of ocean depths requires characterization of the influence of hydrostatic pressure on the permeability of MIMS inlet systems. To simulate measurement conditions in the field, a laboratory apparatus was constructed for control of sample flow rate, temperature, ...

متن کامل

Modeling and Simulation of CO2 Absorption Enhancement in Hollow-Fiber Membrane Contactors using CNT–Water-Based Nanofluids

Absorption of CO2 from a gas mixture containing CO2 and nitrogen by water-based CNT nanofluids in gas–liquid hollow fiber membrane contactor was modeled and solved using COMSOL Multiphysics 5.4. The model assumed partial wetting of the membrane, along with diffusion in the axial and radial directions. In addition, Brownian motion and grazing effects were both considered in the model. The main c...

متن کامل

Reversed-phase membrane inlet mass spectrometry applied to the real-time monitoring of low molecular weight alcohols in chloroform.

Reversed-phase membrane inlet mass spectrometry incorporating a hollow-fiber Nafion membrane has been evaluated for the determination of low molecular weight alcohols in chloroform. The hydrophilic Nafion membrane preferentially transports methanol and ethanol, allowing percentage concentrations of the alcohols to be determined in a chloroform matrix. A linear response was observed for ethanol ...

متن کامل

High-Resolution Measurement of Volatile Organic Compounds Dissolved in Seawater Using Equilibrator Inlet-Proton Transfer Reaction-Mass Spectrometry (EI-PTR-MS)

We have developed an equilibrator inlet-proton transfer reaction-mass spectrometry (EI-PTRMS) system for the high-resolution measurement of the concentrations of multiple volatile organic compounds (VOCs) dissolved in seawater. The equilibration of six VOCs (dimethyl sulfide (DMS), isoprene, propene, acetone, acetaldehyde, and methanol) between seawater samples and the carrier gas, and the resp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003