Laboratory Evaluation of the Influence of Decentration and Pupil Size on the Optical Performance of a Monofocal, Bifocal, and Trifocal Intraocular Lens.

نویسندگان

  • Tamer Tandogan
  • Hyeck Soo Son
  • Chul Young Choi
  • Michael C Knorz
  • Gerd U Auffarth
  • Ramin Khoramnia
چکیده

PURPOSE To assess the influence of decentration and aperture size on the optical quality of different intraocular lenses (IOLs) of the same material, body design, and refractive power using standardized optical bench testing. METHODS Using an optical bench set-up, an aspheric monofocal (CT ASPHINA 409M; Carl Zeiss Meditec, Jena, Germany), an aspheric diffractive bifocal (AT LISA 809M; Carl Zeiss Meditec), and an aspheric diffractive trifocal (AT LISA 839M; Carl Zeiss Meditec) intraocular lens (IOL) were evaluated, each with the same distance power, body design, and material. Modulation transfer function (MTF) values were measured at spatial frequencies of 50 lp/mm and aperture sizes of 3 and 4.5 mm. Each IOL was measured while centered, then decentered by 0.25, 0.5, 0.75, and 1 mm. RESULTS MTF values for the monofocal IOL at far focus with 3- and 4.5-mm aperture size were 0.80/0.80 with maximum reduction to 0.77/0.73 for 1-mm decentration, respectively. Centered IOL MTFs of the bifocal and trifocal IOLs were lower for the far focus at 0.46/0.41 and 0.39/0.26, with reduction at 1-mm decentration to 0.35/0.25 and 0.25/0.18, respectively. Values for near focus of the bifocal and trifocal IOLs reduced from 0.27/0.31 and 0.19/0.18 to 0.2/0.21 and 0.12/0.13, respectively. The trifocal intermediate focus MTF reduced from 0.15/0.10 to 0.12/0.08. MTF values of all three lenses decreased significantly under all conditions with decentration of 0.5 to 0.75 mm. CONCLUSIONS Monofocal lenses were least negatively affected by decentration, with mean optical quality reduction of less than 10% for 1-mm decentration at physiological pupil sizes. For diffractive bifocal and trifocal lenses, optical quality at all distances was significantly reduced if decentration exceeded 0.75 mm, with intermediate focus showing the least reduction. [J Refract Surg. 2017;33(12):808-812.].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro optical quality measurements of three intraocular lens models having identical platform

BACKGROUND With recent advances in technology and introduction of new intraocular lens (IOL) models, surgeons today have the opportunity to choose from various optical designs, which can influence the postoperative quality of vision. In our laboratory study, we compared the optical quality of three different IOLs that use the identical platform and are produced by the same manufacturer. The stu...

متن کامل

Comparison of bifocal and trifocal diffractive and refractive intraocular lenses using an optical bench.

PURPOSE To assess the differences in optical performance of 9 multifocal IOLs using the same optical bench and to propose a possible comparison for surgeons. SETTING Rothschild Foundation, Paris, France. DESIGN Experimental study. METHODS Nine IOLs (Acrysof Restor +3.0 diopter [D] SN6AD1, Acrysof Restor +4.0 D SN60D3, Acrysof aspheric monofocal SN60WF, Acri.Lisa 366D, Finevision Micro F, ...

متن کامل

Halo and Through-Focus Performance of Four Diffractive Multifocal Intraocular Lenses.

PURPOSE To compare, as a function of pupil size, the through-focus performance and halo features of four diffractive intraocular lenses (IOLs). METHODS Three diffractive bifocal IOLs (ReSTOR +2.5 D SV25T0, Tecnis +2.75 D ZKB00, and AT LISA +3.75 D 809M) and a diffractive trifocal IOL (AT LISA tri +3.33 D, +1.66 D 839MP) were tested in vitro in a modified International Organization for Standar...

متن کامل

Psychophysical Vision Simulation of Diffractive Bifocal and Trifocal Intraocular Lenses

PURPOSE The visual performance of monofocal, bifocal, and trifocal intraocular lenses was evaluated by human individuals using a vision simulator device. This allowed investigation of the visual impression after cataract surgery, without the need actually to implant the lenses. METHODS The randomized, double-masked, three-way cross-over study was conducted on 60 healthy male and female subjec...

متن کامل

Optical performance of monofocal versus multifocal intraocular lenses.

In their recent paper, Ortiz et al. studied the optical performance of monofocal and multifocal intraocular lenses (IOLs) in the human eye. Their main conclusion was that of the IOLs studied, the hybrid refractive–diffractive IOLwas the least affected by pupil diameter in terms of intraocular aberrations. This IOL type also showed a smaller increase in optical aberrations during pupil dilation....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 33 12  شماره 

صفحات  -

تاریخ انتشار 2017