Intraoperative Computed Tomography Navigation for Transpedicular Screw Fixation to Treat Unstable Thoracic and Lumbar Spine Fractures

نویسندگان

  • Ching-Yu Lee
  • Meng-Huang Wu
  • Yen-Yao Li
  • Chin-Chang Cheng
  • Chu-Hsiang Hsu
  • Tsung-Jen Huang
  • Robert Wen-Wei Hsu
  • Federico Canavese.
چکیده

Transpedicular screw (TPS) fixation in unstable thoracic and lumbar (TL) spine fractures remains technically difficult because of destroyed anatomical landmarks, unstable gross segments, and discrepancies in anatomic orientation using conventional anatomic landmarks, fluoroscopic guidance, or computed tomography (CT)-based navigation. In this study, we evaluated the safety and accuracy of TPS placement under intraoperative computed tomography (iCT) navigation in managing unstable TL spine fractures.From 2010 to 2013, we retrospectively reviewed the Spine Operation Registry records of patients who underwent posterior instrumented fusion to treat unstable TL spine fractures via the iCT navigation system. An unstable spine fracture was identified as AO/Magerl classification type B or type C.In all, 316 screws in 37 patients with unstable TL spine fractures were evaluated and involved 7 thoracic, 23 thoracolumbar junctional, and 7 lumbar fractures. The accuracy of TPS positioning in the pedicle without breach was 98% (310/316). The average number of iCT scans per patient was 2.1 (range 2-3). The average total radiation dose to patients was 15.8 mSv; the dose per single level exposure was 2.7 mSv. The TPS intraoperative revision rate was 0.6% (2/316) and no neurovascular sequela was observed. TPS fixation using the iCT navigation system obtained a 98% accuracy in stabilizing unstable TL spine fractures. A malplaced TPS could be revised during real-time confirmation of the TPS position, and no secondary operation was required to revise malplaced screws.The iCT navigation system provides accurate and safe management of unstable TL spine fractures. In addition, operating room personnel, including surgeons and nurses, did not need to wear heavy lead aprons as they were not exposed to radiation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

Computed tomography-based navigation-assisted pedicle screw insertion for thoracic and lumbar spine fractures.

BACKGROUND Incorrect placement of pedicle screws may lead to neurovascular injury, so the position is important for the reduction of spinal fractures. CT-based image-guided surgery has been promoted as a means to theoretically improve the accuracy of pedicle screw placement. Patients who underwent CT-based navigation-assisted pedicle screw fixation for thoracic or lumbar fractures were reviewed...

متن کامل

Transpedicular screw fixation in the thoracic and lumbar spine with a novel cannulated polyaxial screw system

OBJECTIVE Transpedicular screws are commonly and successfully used for posterior fixation in spinal instability, but their insertion remains challenging. Even using navigation techniques, there is a misplacement rate of up to 11%. The aim of this study was to assess the accuracy of a novel pedicle screw system. METHODS Thoracic and lumbar fusions were performed on 67 consecutive patients for ...

متن کامل

Unconventional fixation of thoracolumbar fractures using round hole bone plates and transpedicular screws.

BACKGROUND In an attempt to contain the high cost of commercially available pedicle screw systems, several authors have used unconventional alternatives such as locally made plates or dynamic compression plates (DCP) along with cancellous screws for transpedicular fixation of the thoracolumbar spine. These plates, however, allow for a wide range of motion at the plate-screw interphase and the c...

متن کامل

Anterior Transpedicular Screw-Plate System Fixation in the Lower Cervical Spine Fracture Complicated by Spinal Cord Injury: A Case Report

A multilevel contiguous fracture of the subaxial cervical spine represents the severe trauma, and anterior plate fixation with anterior transpedicular screw fixation is a new and reliable fixation pattern for the treat-ment of acute spinal cord injury (ASCI). We present a case of multilevel contiguous fractures in the lower cervical spine without obvious posterior ligamentous complex injury, bu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 94  شماره 

صفحات  -

تاریخ انتشار 2015