Heads-Up Macular Surgery with a 27-Gauge Microincision Vitrectomy System and Minimal Illumination
نویسندگان
چکیده
OBJECTIVE We combined heads-up 3-dimensional (3D) 27-gauge microincision vitrectomy surgery (27GMIVS) with a very low-intensity illumination system. METHODS This study was based on a retrospective, interventional case series of 6 eyes of 6 patients with macular disease. All patients underwent heads-up 3D 27GMIVS and the power of the intraocular illuminator was set to its minimum level, 1% (approximately 0.1 lm), throughout the surgery. RESULTS We found that the procedure was easy when the heads-up 3D system was used, but not through the eyepiece of a microscope. All surgeries were successfully finished without any complications. Postoperative visual acuity was restored or maintained in all eyes during the follow-up period. CONCLUSION Heads-up, 3D system-assisted 27GMIVS with minimal illumination enabled excellent intraoperative visualization of retinal tissues, caused minimal phototoxicity to the macular retinal cells, and might therefore represent the next step in the development of an ideal, minimally invasive method of treating macular disease.
منابع مشابه
Innovations in 27 - Gauge Vitrectomy for Sutureless Microincision
T he common thinking regarding surgical wounds is that “much smaller is much better.” Based on this concept, microincision vitrectomy surgery (MIVS) with 25or 23-gauge instruments has taken over from conventional 20-gauge vitrectomy in many cases, and the technology has evolved radically during the past several years. Along with the development of ergonomic instrumentation and new-generation vi...
متن کاملIntraoperative Optical Coherence Tomography-Assisted 27-Gauge Vitrectomy in Eyes with Vitreoretinal Diseases
OBJECTIVE To report intraoperative optical coherence tomography (iOCT)-assisted 27-gauge microincision vitrectomy surgery (MIVS) in eyes with vitreoretinal disease. METHODS A retrospective, interventional case series performed at a single center, including 6 eyes with retinal disease that underwent iOCT-assisted 27-gauge MIVS. RESULTS The advantages of iOCT were most notable when it was use...
متن کاملOutcomes of 27 Gauge Microincision Vitrectomy Surgery for Posterior Segment Disease.
PURPOSE To report the initial experience, clinical outcomes, and safety profile of 27 gauge pars plana vitrectomy (PPV) in eyes with posterior segment disease. DESIGN Multicenter, retrospective, interventional case series. METHODS setting: Private practice and tertiary care settings. STUDY POPULATION Eyes undergoing 27 gauge PPV for a vitreoretinal surgery indication. INTERVENTION Three...
متن کاملFaster recovery after 25-gauge microincision vitrectomy surgery than after 20-gauge vitrectomy in patients with proliferative diabetic retinopathy
BACKGROUND AND METHODS We compared surgical procedures and outcomes, including duration of recovery period, in eyes with proliferative diabetic retinopathy that underwent 25-gauge microincision vitrectomy surgery with those that underwent 20-gauge vitrectomy. Seventy-two eyes from 53 patients that underwent 20-gauge vitrectomy in 2006 and 87 eyes from 55 patients that underwent 25-gauge vitrect...
متن کاملComparison of Surgically-induced Astigmatism after Combined Phacoemulsification and 23-Gauge Vitrectomy: 2.2-mm vs. 2.75-mm Cataract Surgery
PURPOSE The 2.2-mm microincision cataract surgery and small-gauge vitrectomy system is known to result in less surgically-induced astigmatism (SIA) in comparison to conventional surgical methods. We compared the amounts of SIA after combined phacoemulsification and 23-gauge transconjunctival sutureless vitrectomy (23G-TSV) using the 2.2-mm microincision and 2.75-mm standard incision methods. ...
متن کامل