Tumor oximetry: comparison of 19F MR EPI (FREDOM) and the fiber-optic OxyLiteTM

نویسندگان

  • R. P. Mason
  • D. Zhao
  • A. Constantinescu
  • Andrew Obeid
چکیده

Introduction: Recent development of methods to measure p0, in the clinic has generated data confirming a prognostic relationship between tumor p0, and clinical outcome. These results provide a powerful stimulus for development of enhanced methods for monitoring tumor ~0,. We have been developing a methodFRBDOM (Fluorine Relaxometry using Echo planar imaging for Dynamic Oxygen Mapping), which typically provides p0, measurements at > 50 individual locations in 8 minutes with a precision of l-3 torr. We have now compared this approach with the new commercial OxyLiterM fiber-optic based oxygen monitoring system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of lung tumor oxygenation using FREDOM and TOLD

Introduction: Tumor oxygenation plays an important role in malignant progression, metastasis and response to various therapies. F MR oximetry based on the reporter molecule hexafluorobenzene (HFB) using the FREDOM (Fluorocarbon Relaxometry using Echo planar imaging for Dynamic Oxygen Mapping) approach offers quantitative measurements of pO2 with spatial and temporal resolution allowing the dyna...

متن کامل

COMPARISON OF DIFFERENT GLASS COMPOUNDS FOR INTRINSIC FIBER OPTIC TEMPERATURE SENSORS

Different glasses suitable for temperature sensing in the fiber optic sensors were studied in this article. The phase changes for eight different glass materials were calculated and results were compared. Our results showed that extra dense flint glass is the most sensitive one, while pure silica results in the lowest phase change. In another study the effect of wavelength on the phase variatio...

متن کامل

Hypoxia imaging with the nitroimidazole 18F-FAZA PET tracer: a comparison with OxyLite, EPR oximetry and 19F-MRI relaxometry.

BACKGROUND AND PURPOSE (18)F-FAZA is a nitroimidazole PET tracer that can provide images of tumor hypoxia. However, it cannot provide absolute pO(2) values. To qualify (18)F-FAZA PET, we compared PET images to pO(2) measured by OxyLite, EPR oximetry and (19)F-MRI. MATERIALS AND METHODS Male WAG/Rij rats grafted with rhabdomyosarcoma were used. Tumor oxygenation was modified by gas breathing (...

متن کامل

Fiber - Optic Sensing of Linear Thermal Expansion (RESEARCH NOTES)

The use of a LED fiber-optic sensor to measure displacement and linear thermal expansion is described. It has a sensitivity of about 0.6 mV/mm, a resolution of 1.25 mm, and a dynamic rang of 400 mm for displacement measurements. For thermal expansion, it shows a sensitivity of about 3.5 mV/C, and the experimental linear expansion values are in agreement with those calculated. The reported senso...

متن کامل

A fiber optic sensor for measuring glucose in aqueous solutions

In this paper, the set-up of a multi-mode fiber optic sensor for measuring glucose in aqueous solutions is investigated and evaluated. The basis of this sensor is based on the Fresnel Reflection. In this setup, a helium-neon laser is used as a light source, a fiber optic probe, photocell as detector and a digital multimeter. The statistical analysis of the recorded data shows a highly linear be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000