A tip on using the appropriate wire passer in orthopaedic surgery.
نویسندگان
چکیده
The authors present a technical tip on using the appropriate wire passer while passing cerclage wires around long bones in orthopaedic surgery.
منابع مشابه
Minimally Invasive Surgical Approach to Distal Fibula Fractures: A Technique Tip
Wound complications following ankle fracture surgery are a major concern. Through the use of minimally invasive surgical techniques some of these complications can be mitigated. Recent investigations have reported on percutaneous fixation of distal fibula fractures demonstrating similar radiographic and functional outcomes to traditional open approaches. The purpose of this manuscript is to ...
متن کاملIntrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture
Breakage of DHS guide wire during surgery and its migration into the pelvis through the hip joint is a rare complication and its removal can be very challenging for the surgeon. We share our experience of a similar case wherein we used an ‘iliofemoral’ approach to successfully remove the broken transfixing guidewire from the hip joint. Although iliofemoral approach is similar to the lateral win...
متن کاملImplant Removal Matrix for the Upper Extremity Orthopedic Surgeon
Orthopedic implant removal is a commonly performed procedure. While implant removal can be associated withimproved symptoms, risks of the surgery are notable. Stripped screws, broken and retained hardware, and morbidityassociated with soft tissue compromise during difficult removal are all common. Familiarity with the instruments iscritical to procedure success. The purpose of...
متن کاملCommentary: Percutaneous release of the A1 pulley using a modified Kirschner wire: a cadaveric study.
PURPOSE. To evaluate the outcome of percutaneous release of the A1 pulley in 40 cadaveric fingers using a modified Kirschner wire. METHODS. A 2.5-mm-diameter Kirschner wire measuring >12 cm in length was used. One end of the wire was sharpened into a 'J' shape using a grinder. The J-shaped tip featured a blunt, elongated lower tip, a sharp J-shaped curve, and a blunt upper tip. Completeness of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica Belgica
دوره 72 5 شماره
صفحات -
تاریخ انتشار 2006