Diffusion measurement in ferrous infused gel dosimeters
نویسندگان
چکیده
Background: The compositions of Ferrous sulphate, Agarose and Xylenol orange dye (FAX) and Ferrous sulphate, Gelatin and Xylenol orange dye (FGX) in solution of distilled water and sulphuric acid are two tissue-equivalent gel dosimeters. Ionizing radiation causes oxidation of Fe ion to Fe ions which diffuse through the gel matrix and blur the image of absorbed dose over a period of hours after irradiation. Materials and methods: 25 mM sulphuric acid, 0.4 mM ferrous ammonium sulphate, 0.2 mM xylenol orange dye and 1% by weight agarose in distilled water named FAX and 0.1 mM ferrous ammonium sulphate, 0.1 mM xylenol orange dye, 50 mM sulphuric acid and 5% by weight gelatin in distilled water named FGX are used as two gel dosimeters. All chemicals were supplied by Sigma Aldridge Company, Germany. The gels were poured in Perspex casts and were irradiated to a beam of X ray from linear accelerators or x ray machine. Results: In this study diffusion coefficients of FAX and FGX dosimeters have been measured through a computer program for different temperatures. The ferric ion diffusion coefficient (D) for the FAX and FGX dosimeters were measured as (1.19 ± 0.03) x 10 cm.hr and (0.83 ± 0.03) x 10 cm.hr respectively at room temperature. Conclusion: For both dosimeters the diffusion coefficients decreased with gel storage temperatures down to 6C. FGX dosimeters have advantage of lower diffusion coefficient for a specified temperature. Iran. J. Radiat. Res.; 2003; 1(2): 79 – 86.
منابع مشابه
Diffusion measurement in ferrous infused gel dosimeters
Background: The compositions of Ferrous sulphate, Agarose and Xylenol orange dye (FAX) and Ferrous sulphate, Gelatin and Xylenol orange dye (FGX) in solution of distilled water and sulphuric acid are two tissue-equivalent gel dosimeters. Ionizing radiation causes oxidation of Fe2+ ion to Fe3+ ions which diffuse through the gel matrix and blur the image of absorbed dose over a period of hours af...
متن کاملMeasurement of ferric ion diffusion coefficient in Fricke-infused agarose gel from MR image intensity changes
Abstract-A mathematical modeling was adopted to calculate the ferric ion diffusion coefficient based on the radiation induced magnetic resonance (MR) image intensity change in Fricke-agarose gels. A fast magnetic resonance imaging acquisition technique was employed to avoid the smearing of acquired data due to diffusion over an extended period of time. Our results showed that for a Fricke-agaro...
متن کاملRadiological properties of nanocomposite Fricke gel dosimeters for heavy ion beams
The radiological properties of nanocomposite Fricke gel (NC-FG) dosimeters prepared with different concentrations of nano-clay, perchloric acid and ferrous ions in deaerated conditions were investigated under carbon and argon ion beam irradiation covering a linear-energy-transfer (LET) range of 10 to 3000 eV/nm. We found that NC-FG exhibits radiological properties distinct from those of convent...
متن کاملMagnetic resonance in polymer gel dosimetry: techniques and optimization
1. Introduction Magnetic resonance imaging (MRI) can non-invasively and non-destructively probe the magnetization of hydrogen atoms on water molecules in large objects with a high spatial resolution, and in three dimensions. This unique combination of properties is exploited in polymer gel dosimetry since original gel dosimeters, in which viscosity changes were measured and related to the absor...
متن کاملApplication of Optical CT Scanning in Three-Dimensional Radiation Dosimetry
There has been much research effort in the development of an accurate and reliable threedimensional dose verification system, prompted by the advances of technologies in radiation treatment of cancer patients. New radiotherapy techniques such as intensity modulated radiation therapy (IMRT), stereotactic radiosurgery (SRS) and high dose rate (HDR) brachytherapy are aimed at dose deliveries that ...
متن کامل