Blood glucose measurement by using hollow optical fiber-based attenuated total reflection probe.
نویسندگان
چکیده
A noninvasive glucose monitoring system based on mid-infrared, attenuated total reflection spectroscopy using a hollow optical fiber probe is developed. Owing to the flexible fiber probe, measurement of oral mucosa, where blood capillaries are near the skin surface, is possible. Blood glucose levels are measured by detecting the peak intensity of glucose absorption bands, and the experimental results showed that the reproducibility of the measurement is high enough for monitoring blood glucose.
منابع مشابه
Forward-viewing photoacoustic imaging probe with bundled ultra-thin hollow optical fibers
A photoacoustic imaging system composed of a flexible bundle of thin hollow-optical fibers is proposed for endoscopic diagnosis. In this system, a bundle of 127 hollow-optical fibers with an inner diameter of 100 μm was fabricated. The total diameter of the bundle was 2.1 mm, and the minimum bending radius was around 10 mm. Owing to the small numerical aperture of hollow optical fibers, a high ...
متن کاملTip sensor probe for changing refractive index measurement in small volumes
In this paper, a tapered tip optical fiber probe sensor for localized refractive index (RI) measurements is presented. This sensor’s interaction with analytes is confined to a few micro-meters which makes it a promising candidate for in-vivo or even intra-cellular RI monitoring. This tapered tip was simply fabricated by etching optical fiber with hydrofluoric acid to a conic shape with a sub-m...
متن کاملDevelopment of a Disposable Electrochemical Sensor based on Nanocomposite/Ionic Liquid Assisted Hollow Fiber-Graphite Electrode for Measurement of Lorazepam Using Central Composite Design
In this study a new method of preconcentration, separation and efficient measuring of so-called hollow fiber solid / liquid phase microextraction has been introduced for the determination of trace amounts of lorazepam (LRZ) in water samples, urine and hair using differential pulse voltammetry. To this end, a hybrid adsorbent material was used that involved ionic liquid assisted magnetic multi-w...
متن کاملCritical Review of Pipeline Scale Measurement Technologies
Submit Manuscript | http://medcraveonline.com Abbreviations: PMMA: Poly Methyl Methacrylate; TSMR: Thickness Shear Mode Resonator; IECOFS: Intrinsic Exposed Core Optical Fiber Sensor; ATR: Attenuated Total Reflectance; DTS: Distributed Temperature Sensor; CPSM: Cylindrical Phase Shift Migration Algorithm; ANNs: Artificial Neural Networks; MFL: Magnetic Flux Leakage; ICS: Internal Corrosion Sens...
متن کاملCritical Review of Pipeline Scale Measurement Technologies
Submit Manuscript | http://medcraveonline.com Abbreviations: PMMA: Poly Methyl Methacrylate; TSMR: Thickness Shear Mode Resonator; IECOFS: Intrinsic Exposed Core Optical Fiber Sensor; ATR: Attenuated Total Reflectance; DTS: Distributed Temperature Sensor; CPSM: Cylindrical Phase Shift Migration Algorithm; ANNs: Artificial Neural Networks; MFL: Magnetic Flux Leakage; ICS: Internal Corrosion Sens...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 19 5 شماره
صفحات -
تاریخ انتشار 2014