Practical dose delivery verification of craniospinal IMRT

نویسندگان

  • Young K Lee
  • Anthony T Kim
  • Peiying Zhao
  • Aliaksandr Karotki
چکیده

Craniospinal irradiation (CSI) using IMRT allows dose sparing to organs-at-risk (OAR) whilst conforming the dose to the target volume. Due to the complexity of treatment involving several isocenters, the dose distribution created by the inverse-planned segmented fields must be verified prior to treatment. We propose and test methods to verify dose delivery using commonly available dosimetry equipment for commissioning and routine patient-specific dose verification of craniospinal IMRT. Ten patients treated with conventional CSI were retrospectively planned with a 3-isocenter (cranial, upper spine, and lower spine) IMRT technique. The isocenters were placed 25-27 cm away from each other in the longitudinal direction but in the same lateral and anterioposterior positions. The planning target volume (PTV) was defined as the brain with a 0.5 cm margin and spinal canal with a 1.0 cm margin. The plans were prescribed to 36 Gy in 20 fractions to the PTV mean dose. Eleven beams (five cranial, three upper spine, and three lower spine) were optimized simultaneously. The dose delivered by the IMRT plans was then recalculated on several different phantoms and measured using the following methods: 1) ionization chamber inserted in a cylindrical phantom, positioned in the junction regions between cranial/upper-spine isocenters and upper-/lower-spine isocenters; 2) MapCHECK centered in the overlap regions; and 3) ArcCHECK measurement with beams from each isocenter. For 1) ± 3% dose difference and for 2) and 3) ≥ 95% of measured points with a γ-index < 1 for 3% dose difference and 3 mm distance-to-agreement were deemed clinically acceptable. The median (range) planned to measured dose differences for the ionization chamber is 0.4% (-1.5% to 3.0%) for the cranial/upper-spine field and 1.8% (-0.8% to 2.6%) for the upper-/lower-spine field overlap region. The median (range) percentage of MapCHECK diodes with a γ index < 1 for 3%/3 mm criterion is 98.0% (95.3% to 99.7%) for the cranial/upper-spine and 97.3% (95.0% to 99.6%) for the upper-/lower-spine field overlap regions. The median (range) percentage of ArcCHECK diodes with a γ index < 1 for 3%/3 mm criterion is 99.7% (97.1% to 100%). Three different methods of verifying craniospinal IMRT were compared and tested. All techniques offer different benefits and together can be used for 1) commissioning the treatment technique and, separately, for 2) patient-specific pretreatment verification measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional gel dosimetry for dose volume histogram verification in compensator-based IMRT

Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...

متن کامل

Comparing the results of 3D treatment planning and practical dosimetry in craniospinal radiotherapy using Rando phantom

Background: Craniospinal radiotherapy faces technical challenges which are due to the sensitivity of the location in which the gross tumor is, and to organs at risk around planning target volume. Using modern treatment planning systems causes a reduction in the complexities of the treatment techniques. The most effective method to assess the dosimetric accuracy and the validity of the ...

متن کامل

Design of an Anthropomorphic Intensity Modulated Radiation Therapy Quality Assurance Phantom

The dynamic nature of IMRT delivery poses unique problems relating to the accurate and reproducible quality assurance of dose delivery. The usefulness of point detectors is limited to static fields and regions within low dose-gradients for treatment verification. However, dose distributions generated in intensity modulated radiation therapy (IMRT) often have complex shapes with high dose gradie...

متن کامل

The Quality Control of Intensity Modulated Radiation Therapy (IMRT) for ONCOR Siemens Linear Accelerators Using Film Dosimetry

Introduction Intensity Modulated Radiation Therapy (IMRT) has made a significant progress in radiation therapy centers in recent years. In this method, each radiation beam is divided into many subfields that create a field with a modulated intensity. Considering the complexity of this method, the quality control for IMRT is a topic of interest for researchers. This article is about the various ...

متن کامل

Pii: S0167-8140(01)00497-2

Background and purpose: Although intensity modulated radiotherapy (IMRT) is a step forward in comparison to conventional, static beam delivery, quality assurance is more complex and labour intensive, demanding detailed two-dimensional dosimetric verification. Regardless of the technique used for measuring the dose distribution, what is essential to the implementation of routine verification of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015